Solder Reflow and Handling
The FW322 has a moisture sensitivity classification of 3, which is determined in accordance with the standard IPC/
JEDEC J-STD-020, Revision A, titled Moisture/Reflow Sensitivity Classification for Nonhermetic Solid State Sur-
face Mount Devices. Handling of this device should be in accordance with standard IPC/JEDEC J-STD-033, titled
Standard for Handling, Packing, Shipping and Use of Moisture/Reflow Sensitive Surface Mount Devices.
Up to three reflows may be performed using a temperature profile that meets the requirements of Table 3 in stan-
dard IPC/JEDEC J-STD-020. The requirements of IPC/JEDEC J-STD-033 must be met. The maximum allowable
body temperature for the FW322 is 220 °C —225 °C. This is the actual tolerance that Agere uses to test the devices
during preconditioning.
Absolute Maximum Voltage/Temperature Ratings
Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are abso-
lute stress ratings only. Functional operation of the device is not implied at these or any other conditions in excess
of those given in the operational sections of the data sheet. Exposure to absolute maximum ratings for extended
periods can adversely affect device reliability.
Table 73. Absolute Maximum Ratings
Agere Systems Inc.
Supply Voltage Range
Input Voltage Range
Output Voltage Range at Any Output
Operating Free Air Temperature
Storage Temperature Range
Parameter
Symbol
V
T
V
T
V
DD
stg
O
A
I
PCI PHY/Link Open Host Controller Interface
−0.5
−0.5
Min
–65
3.0
0
V
V
DD
DD
Max
150
FW322 06 1394a
3.6
70
+ 0.5
+ 0.5
Unit
°C
°C
V
V
V
87