ADV7340EBZ AD [Analog Devices], ADV7340EBZ Datasheet - Page 26

no-image

ADV7340EBZ

Manufacturer Part Number
ADV7340EBZ
Description
Manufacturer
AD [Analog Devices]
Datasheet
ADV7340/ADV7341
MPU PORT DESCRIPTION
Devices such as a microprocessor can communicate with the
ADV7340/ADV7341 through one of the following protocols:
After power-up or reset, the MPU port is configured for I
operation. SPI operation can be invoked at any time by
following the procedure outlined in the SPI Operation section.
I
The ADV7340/ADV7341 support a 2-wire serial (I
compatible) microprocessor bus driving multiple peripherals.
This port operates in an open-drain configuration. Two inputs,
serial data (SDA) and serial clock (SCL), carry information
between any device connected to the bus and the ADV7340/
ADV7341. Each slave device is recognized by a unique address.
The ADV7340/ADV7341 have four possible slave addresses for
both read and write operations. These are unique addresses for
each device and are illustrated in Figure 48. The LSB either sets a
read or write operation. Logic 1 corresponds to a read operation,
while Logic 0 corresponds to a write operation. A1 is controlled
by setting the ALSB/ SPI_SS pin of the ADV7340/ADV7341 to
Logic 0 or Logic 1.
To control the various devices on the bus, use the following
protocol. The master initiates a data transfer by establishing a
start condition, defined by a high-to-low transition on SDA
while SCL remains high. This indicates that an address/data
stream follows. All peripherals respond to the start condition
and shift the next eight bits (7-bit address + R/ W bit). The bits
are transferred from MSB down to LSB. The peripheral that
recognizes the transmitted address responds by pulling the data
2
C OPERATION
2-wire serial (I
4-wire serial (SPI-compatible) bus
1
Figure 48. ADV7340 Slave Address = 0xD4 or 0xD6
1
2
C-compatible) bus
0
1
0
ALSB/SPI_SS
1
CONTROL
SET UP BY
ADDRESS
A1
READ/WRITE
CONTROL
0
1
WRITE
READ
X
2
C-
2
C
Rev. 0 | Page 26 of 88
line low during the ninth clock pulse. This is known as an
acknowledge bit. All other devices withdraw from the bus at
this point and maintain an idle condition. The idle condition
occurs when the device monitors the SDA and SCL lines
waiting for the start condition and the correct transmitted
address. The R/ W bit determines the direction of the data.
Logic 0 on the LSB of the first byte means that the master writes
information to the peripheral. Logic 1 on the LSB of the first byte
means that the master reads information from the peripheral.
The ADV7340/ADV7341 act as a standard slave device on the
bus. The data on the SDA pin is eight bits long, supporting the
7-bit addresses plus the R/ W bit. It interprets the first byte as
the device address and the second byte as the starting
subaddress. There is a subaddress auto-increment facility. This
allows data to be written to or read from registers in ascending
subaddress sequence starting at any valid subaddress. A data
transfer is always terminated by a stop condition. The user can
also access any unique subaddress register on a one-by-one
basis without updating all the registers.
Stop and start conditions can be detected at any stage during
the data transfer. If these conditions are asserted out of
sequence with normal read and write operations, they cause an
immediate jump to the idle condition. During a given SCL high
period, the user should issue only a start condition, a stop
condition, or a stop condition followed by a start condition. If
an invalid subaddress is issued by the user, the ADV7340/
ADV7341 do not issue an acknowledge and do return to the idle
condition. If the user utilizes the auto-increment method of
addressing the encoder and exceeds the highest subaddress, the
following actions are taken:
In read mode, the highest subaddress register contents are
output until the master device issues a no acknowledge.
This indicates the end of a read. A no acknowledge
condition occurs when the SDA line is not pulled low on
the ninth pulse.
In write mode, the data for the invalid byte is not loaded
into any subaddress register, a no acknowledge is issued by
the ADV7340/ADV7341, and the parts return to the idle
condition.

Related parts for ADV7340EBZ