MC68HC908JL8 MOTOROLA [Motorola, Inc], MC68HC908JL8 Datasheet - Page 165

no-image

MC68HC908JL8

Manufacturer Part Number
MC68HC908JL8
Description
Motorola reserves the right to make changes without further notice to any products herein
Manufacturer
MOTOROLA [Motorola, Inc]
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MC68HC908JL8CDW
Manufacturer:
MOTOROLA/摩托罗拉
Quantity:
20 000
Part Number:
MC68HC908JL8CDWE
Manufacturer:
FREESCALE
Quantity:
20 000
Part Number:
MC68HC908JL8CFA
Manufacturer:
Freescale Semiconductor
Quantity:
10 000
Part Number:
MC68HC908JL8CFA
Manufacturer:
FREESCALE
Quantity:
20 000
Part Number:
MC68HC908JL8CFAE
Manufacturer:
FREESCALE
Quantity:
1 240
Part Number:
MC68HC908JL8CFAE
Manufacturer:
Freescale Semiconductor
Quantity:
10 000
Part Number:
MC68HC908JL8CFAE
Manufacturer:
FREESCALE
Quantity:
1 240
Part Number:
MC68HC908JL8CFAE
Manufacturer:
FREESCALE
Quantity:
20 000
Part Number:
MC68HC908JL8CP
Manufacturer:
FREESCALE Semiconductor
Quantity:
388
Part Number:
MC68HC908JL8CP
Manufacturer:
FRE/MOT
Quantity:
20 000
Part Number:
MC68HC908JL8CSPE
Manufacturer:
SINOPOWER
Quantity:
24 000
Part Number:
MC68HC908JL8CSPE
Manufacturer:
Freescale Semiconductor
Quantity:
135
Part Number:
MC68HC908JL8CSPE
Manufacturer:
FREESCALE
Quantity:
51
Part Number:
MC68HC908JL8MFAE
Manufacturer:
Freescale Semiconductor
Quantity:
10 000
MC68HC908JL8
MOTOROLA
Rev. 2.0
CHxF — Channel x Flag Bit
CHxIE — Channel x Interrupt Enable Bit
MSxB — Mode Select Bit B
MSxA — Mode Select Bit A
When channel x is an input capture channel, this read/write bit is set
when an active edge occurs on the channel x pin. When channel x is
an output compare channel, CHxF is set when the value in the TIM
counter registers matches the value in the TIM channel x registers.
When TIM CPU interrupt requests are enabled (CHxIE = 1), clear
CHxF by reading TIM channel x status and control register with CHxF
set and then writing a logic 0 to CHxF. If another interrupt request
occurs before the clearing sequence is complete, then writing logic 0
to CHxF has no effect. Therefore, an interrupt request cannot be lost
due to inadvertent clearing of CHxF.
Reset clears the CHxF bit. Writing a logic 1 to CHxF has no effect.
This read/write bit enables TIM CPU interrupt service requests on
channel x.
Reset clears the CHxIE bit.
This read/write bit selects buffered output compare/PWM operation.
MSxB exists only in the TIM1 channel 0 and TIM2 channel 0 status
and control registers.
Setting MS0B disables the channel 1 status and control register and
reverts TCH1 to general-purpose I/O.
Reset clears the MSxB bit.
When ELSxB:ELSxA ≠ 0:0, this read/write bit selects either input
capture operation or unbuffered output compare/PWM operation.
See
Freescale Semiconductor, Inc.
For More Information On This Product,
1 = Input capture or output compare on channel x
0 = No input capture or output compare on channel x
1 = Channel x CPU interrupt requests enabled
0 = Channel x CPU interrupt requests disabled
1 = Buffered output compare/PWM operation enabled
0 = Buffered output compare/PWM operation disabled
1 = Unbuffered output compare/PWM operation
0 = Input capture operation
Table
Timer Interface Module (TIM)
Go to: www.freescale.com
10-3.
Timer Interface Module (TIM)
Technical Data
I/O Registers
165

Related parts for MC68HC908JL8