LPC2458FET180,551 NXP Semiconductors, LPC2458FET180,551 Datasheet - Page 508

IC ARM7 MCU FLASH 512K 180TFBGA

LPC2458FET180,551

Manufacturer Part Number
LPC2458FET180,551
Description
IC ARM7 MCU FLASH 512K 180TFBGA
Manufacturer
NXP Semiconductors
Series
LPC2400r
Datasheets

Specifications of LPC2458FET180,551

Core Processor
ARM7
Core Size
16/32-Bit
Speed
72MHz
Connectivity
CAN, EBI/EMI, Ethernet, I²C, Microwire, MMC, SPI, SSI, SSP, UART/USART, USB OTG
Peripherals
Brown-out Detect/Reset, DMA, I²S, POR, PWM, WDT
Number Of I /o
136
Program Memory Size
512KB (512K x 8)
Program Memory Type
FLASH
Ram Size
98K x 8
Voltage - Supply (vcc/vdd)
3 V ~ 3.6 V
Data Converters
A/D 8x10b; D/A 1x10b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
180-TFBGA
Processor Series
LPC24
Core
ARM7TDMI-S
Data Bus Width
32 bit
Data Ram Size
98 KB
Interface Type
CAN, Ethernet, I2C, I2S, IrDA, SPI, SSP, UART, USB
Maximum Clock Frequency
72 MHz
Number Of Programmable I/os
136
Number Of Timers
4
Operating Supply Voltage
3.3 V
Maximum Operating Temperature
+ 85 C
Mounting Style
SMD/SMT
3rd Party Development Tools
MDK-ARM, RL-ARM, ULINK2, SAB-TFBGA180
Minimum Operating Temperature
- 40 C
On-chip Adc
10 bit, 8 Channel
On-chip Dac
10 bit, 1 Channel
Package
180TFBGA
Device Core
ARM7TDMI-S
Family Name
LPC2000
Maximum Speed
72 MHz
For Use With
622-1023 - BOARD SCKT ADAPTER FOR TFBGA180622-1005 - USB IN-CIRCUIT PROG ARM7 LPC2K
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-
Lead Free Status / Rohs Status
 Details
Other names
568-4258
935282454551
LPC2458FET180-S

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
LPC2458FET180,551
Manufacturer:
MICROCHIP
Quantity:
1 103
Part Number:
LPC2458FET180,551
Manufacturer:
NXP Semiconductors
Quantity:
10 000
NXP Semiconductors
UM10237_4
User manual
receive interrupt whenever a CAN message is accepted and received. Software has to
move the received message out of the receive buffer from the according CAN controller
into the user RAM.
several CAN channels for further processing, the CAN Gateway block was extended by a
so-called FullCAN receive function. This additional feature uses an internal message
handler to move received FullCAN messages from the receive buffer of the according
CAN controller into the FullCAN message object data space of Look-up Table RAM.
When fullCAN mode is enabled, the Acceptance Filter itself takes care of receiving and
storing messages for selected Standard ID values on selected CAN buses, in the style of
“FullCAN” controllers.
In order to set this bit and use this mode, two other conditions must be met with respect to
the contents of Acceptance Filter RAM and the pointers into it:
When these conditions are met and eFCAN is set:
To cover dashboard like applications where the controller typically receives data from
The Standard Frame Individual Start Address Register (SFF_sa) must be greater than
or equal to the number of IDs for which automatic receive storage is to be done, times
two. SFF_sa must be rounded up to a multiple of 4 if necessary.
The EndOfTable register must be less than or equal to 0x800 minus 6 times the
SFF_sa value, to allow 12 bytes of message storage for each ID for which automatic
receive storage will be done.
The area between the start of Acceptance Filter RAM and the SFF_sa address, is
used for a table of individual Standard IDs and CAN Controller/bus identification,
sorted in ascending order and in the same format as in the Individual Standard ID
table (see
page
there are an odd number of “FullCAN” ID’s, at least one entry in this table must be so
marked.
The first (SFF_sa)/2 IDindex values are assigned to these automatically-stored ID’s.
That is, IDindex values stored in the Rx Frame Status Register, for IDs not handled in
this way, are increased by (SFF_sa)/2 compared to the values they would have when
eFCAN is 0.
When a Standard ID is received, the Acceptance Filter searches this table before the
Standard Individual and Group tables.
When a message is received for a controller and ID in this table, the Acceptance filter
reads the received message out of the CAN controller and stores it in Acceptance
Filter RAM, starting at (EndOfTable) + its IDindex*12.
The format of such messages is shown in
499). Entries can be marked as “disabled” as in the other Standard tables. If
Figure 18–78 “Entry in FullCAN and individual standard identifier tables” on
Rev. 04 — 26 August 2009
Chapter 18: LPC24XX CAN controllers CAN1/2
Table
18–454.
UM10237
© NXP B.V. 2009. All rights reserved.
508 of 792