PIC18LF2410T-I/SO Microchip Technology, PIC18LF2410T-I/SO Datasheet - Page 233

IC MCU FLASH 8KX16 28SOIC

PIC18LF2410T-I/SO

Manufacturer Part Number
PIC18LF2410T-I/SO
Description
IC MCU FLASH 8KX16 28SOIC
Manufacturer
Microchip Technology
Series
PIC® 18Fr

Specifications of PIC18LF2410T-I/SO

Core Processor
PIC
Core Size
8-Bit
Speed
40MHz
Connectivity
I²C, SPI, UART/USART
Peripherals
Brown-out Detect/Reset, HLVD, POR, PWM, WDT
Number Of I /o
25
Program Memory Size
16KB (8K x 16)
Program Memory Type
FLASH
Ram Size
768 x 8
Voltage - Supply (vcc/vdd)
2 V ~ 5.5 V
Data Converters
A/D 10x10b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
28-SOIC (7.5mm Width)
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-
21.2
The following steps are needed to set up the HLVD
module:
1.
2.
3.
4.
5.
6.
21.3
When the module is enabled, the HLVD comparator
and voltage divider are enabled and will consume static
current. The total current consumption, when enabled,
is specified in electrical specification parameter D022B.
FIGURE 21-2:
© 2009 Microchip Technology Inc.
Disable the module by clearing the HLVDEN bit
(HLVDCON<4>).
Write the value to the HLVDL3:HLVDL0 bits that
selects the desired HLVD trip point.
Set the VDIRMAG bit to detect high voltage
(VDIRMAG = 1) or low voltage (VDIRMAG = 0).
Enable the HLVD module by setting the
HLVDEN bit.
Clear the HLVD interrupt flag (PIR2<2>), which
may have been set from a previous interrupt.
Enable the HLVD interrupt if interrupts are
desired by setting the HLVDIE and GIE bits
(PIE<2> and INTCON<7>). An interrupt will not
be generated until the IRVST bit is set.
CASE 1:
CASE 2:
HLVD Setup
Current Consumption
Enable HLVD
Enable HLVD
HLVDIF
HLVDIF
IRVST
IRVST
V
V
DD
DD
LOW-VOLTAGE DETECT OPERATION (VDIRMAG =
Internal Reference is stable
Internal Reference is stable
T
T
IVRST
IVRST
HLVDIF may not be set
Depending on the application, the HLVD module does
not need to be operating constantly. To decrease the
current requirements, the HLVD circuitry may only
need to be enabled for short periods where the voltage
is checked. After doing the check, the HLVD module
may be disabled.
21.4
The internal reference voltage of the HLVD module,
specified in electrical specification parameter D420,
may be used by other internal circuitry, such as the
Programmable Brown-out Reset. If the HLVD or other
circuits using the voltage reference are disabled to
lower the device’s current consumption, the reference
voltage circuit will require time to become stable before
a low or high-voltage condition can be reliably
detected. This start-up time, T
is independent of device clock speed. It is specified in
electrical specification parameter 36.
The HLVD interrupt flag is not enabled until T
expired and a stable reference voltage is reached. For
this reason, brief excursions beyond the set point may
not be detected during this interval. Refer to
Figure 21-2 or Figure 21-3.
HLVDIF cleared in software,
HLVDIF remains set since HLVD condition still exists
PIC18F2X1X/4X1X
HLVD Start-up Time
HLVDIF cleared in software
0
)
HLVDIF cleared in software
IRVST
DS39636D-page 235
, is an interval that
V
V
LVD
LVD
IRVST
has