MC68HC908JB16DW Freescale Semiconductor, MC68HC908JB16DW Datasheet - Page 153

no-image

MC68HC908JB16DW

Manufacturer Part Number
MC68HC908JB16DW
Description
IC MCU 16K FLASH 6MHZ USB 28SOIC
Manufacturer
Freescale Semiconductor
Series
HC08r
Datasheet

Specifications of MC68HC908JB16DW

Core Processor
HC08
Core Size
8-Bit
Speed
6MHz
Connectivity
SCI, USB
Peripherals
LED, LVD, POR, PWM
Number Of I /o
21
Program Memory Size
16KB (16K x 8)
Program Memory Type
FLASH
Ram Size
384 x 8
Voltage - Supply (vcc/vdd)
4 V ~ 5.5 V
Oscillator Type
Internal
Operating Temperature
0°C ~ 70°C
Package / Case
28-SOIC (7.5mm Width)
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Eeprom Size
-
Data Converters
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MC68HC908JB16DW
Manufacturer:
FREESCALE
Quantity:
20 000
Part Number:
MC68HC908JB16DWE
Manufacturer:
MOTOROLA/摩托罗拉
Quantity:
20 000
MC68HC908JB16
Freescale Semiconductor
NOTE:
NOTE:
Rev. 1.1
TOF — TIM Overflow Flag Bit
TOIE — TIM Overflow Interrupt Enable Bit
TSTOP — TIM Stop Bit
Do not set the TSTOP bit before entering wait mode if the TIM is required
to exit wait mode.
TRST — TIM Reset Bit
Setting the TSTOP and TRST bits simultaneously stops the TIM counter
at a value of $0000.
This read/write flag is set when the TIM counter reaches the modulo
value programmed in the TIM counter modulo registers. Clear TOF by
reading the TIM status and control register when TOF is set and then
writing a logic 0 to TOF. If another TIM overflow occurs before the
clearing sequence is complete, then writing logic 0 to TOF has no
effect. Therefore, a TOF interrupt request cannot be lost due to
inadvertent clearing of TOF. Reset clears the TOF bit. Writing a
logic 1 to TOF has no effect.
This read/write bit enables TIM overflow interrupts when the TOF bit
becomes set. Reset clears the TOIE bit.
This read/write bit stops the TIM counter. Counting resumes when
TSTOP is cleared. Reset sets the TSTOP bit, stopping the TIM
counter until software clears the TSTOP bit.
Setting this write-only bit resets the TIM counter and the TIM
prescaler. Setting TRST has no effect on any other registers.
Counting resumes from $0000. TRST is cleared automatically after
the TIM counter is reset and always reads as logic 0. Reset clears the
TRST bit.
1 = TIM counter has reached modulo value
0 = TIM counter has not reached modulo value
1 = TIM overflow interrupts enabled
0 = TIM overflow interrupts disabled
1 = TIM counter stopped
0 = TIM counter active
1 = Prescaler and TIM counter cleared
0 = No effect
Timer Interface Module (TIM)
Timer Interface Module (TIM)
Technical Data
153