CS1W-CN224 Omron, CS1W-CN224 Datasheet - Page 11

no-image

CS1W-CN224

Manufacturer Part Number
CS1W-CN224
Description
"CABLE,CS1/C200H PRO27,2m"
Manufacturer
Omron
Datasheets

Specifications of CS1W-CN224

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Further improvements to communications functions. Seamless networks increase production site
transparency
4
The evolution of the
SYSMAC CS1 is
accelerating advances
in the production site.
The Solution for Communicating
across Network Levels
A Wide Range of Systems,
from Small-scale to Large
High Event Responsiveness and High-speed Instruction Execution
The SYSMAC CS1 enables FINS
message communications across a
maximum of eight levels (See note)
(using CX-Programmer Ver. 4.0 or higher)
in comparison with three levels in previous
OMRON systems
Expansion up to eight levels lets you build
a seamless communications system for
sending FINS messages across multiple
levels of Ethernet and Controller Link
networks.
OMRON offers a full lineup of reliable
PLCs including the "flagship" CS1 Series,
and ranging from the small-scale CQM1H
to the large-scale CV Series. The CS1
Series meets the needs not only of small-
scale to large-scale systems, but of
distributed systems as well. This allows
the construction of the optimum system for
the scale and applications of the
production site.
The new CS1 has an operating mode that
allows parallel processing for program
execution and peripheral services. This
has the following benefits.
Note: For CPU Unit Ver. 2.0 or later.
Peripheral services cannot
be executed in shorter period
than cycle time.
Fast exchange with host computers of large
amounts of data, without dependence on the
program capacity of the new CS1.
Smooth refreshing of data exchanged with
SCADA software without variations in timing.
Cycle time not affected if communications
traffic or networks increase when expanding
facilities in the future.
Peripheral service
I/O refresh
Normal mode
(Instruction execution)
I/O refresh
Parallel processing
Flexible System Building
Based on the DeviceNet
The CS1 Series supports the worldwide
multivendor bus standard, DeviceNet.
Component connections in a multivendor
environment are greatly enhanced by
connecting to up to 64 nodes for a wide
range of FA applications, and by device
profiles and configurator tools that ensure
high reliability and easy maintenance.
Production systems can be configured
even more flexibly by incorporating
products such as the MULTIPLE I/O
TERMINAL.
Functions for Better Ethernet
Support
Ethernet is becoming an increasingly
important standard for information
networks. Up to eight socket interfaces for
TCP/IP and UDP/IP are supported, in
addition to FINS messages, FTP file
transfers, and mail notification, so that
production management can now be
organically linked with the production site.
Parallel processing mode
Peripheral servicing
(Peripheral servicing)
Can be executed
in shorter period
than cycle time.
Host
SCADA software
CS1
Fast large-volume data
exchange
No variations in data
exchange timing
Response time:
Approx. 1/3
Sending/receiving FINS
commands and other
event processing.
Event services with Special
I/O Units, CPU Bus Units,
and Inner Boards.
Peripheral and RS-232C
port servicing.
Event services using
Communications Board.
Peripheral services
independent from
cycle time.
Cycle time
257

Related parts for CS1W-CN224