Specifications - Power Supply Units
Note: 1. Disconnect the Power Supply Unit’s LG terminal from the GR terminal when testing insulation and dielectric strength.
278
Item
Power Supply Unit
Supply voltage
Operating voltage range
Power consumption
Inrush current
Output capacity
Output terminal
RUN output
(See Note 2.)
Insulation resistance
Dielectric strength
Noise immunity
Vibration resistance
Shock resistance
Ambient operating tempera-
ture
Ambient operating humidity 10% to 90% (with no condensation)
Atmosphere
Ambient storage tempera-
ture
Grounding
Enclosure
Weight
CPU Rack Dimensions (mm)
(See note 3.)
Product standards
2. Only when mounted to a Backplane.
3. Depth is 153 mm for C200HW-PA209R.
4. Enquire separately for general specifications of Process I/O Units.
Specifications
C200HW-PA204
100 to 120 V AC or 200 to 240 V AC, 50/60 Hz
85 to 132 V AC or 170 to 264 V AC
120 VA max.
30 A max.
4.6 A, 5 V DC (including CPU Unit power)
0.625 A, 26 V DC
Total: 30 W
Not provided
Not provided
20 M min. (at 500 V DC) between AC external and GR terminals (See Note 1.)
2,300 V AC 50/60 Hz for 1 min between AC external and GR terminals (See Note 1.)
Leakage current: 10 mA max.
1,000 V AC 50/60 Hz for 1 min between AC external and GR terminals (See Note 1.)
Leakage current: 10 mA max.
Conforms to IEC61000-4-4, 2 kV (power lines)
10 to 57 Hz, 0.075-mm amplitude, 57 to 150 Hz, acceleration: 9.8 m/s
(Sweep time 8 min 10 = total time 80 min.)
CPU Unit mounted to a DIN rail: 2 to 55 Hz, 2.9 m/s
147 m/s
0 to 55 C
Must be free from corrosive gases.
–20 to 75 C (excluding battery)
Less than 100
IP20, intended for panel mounting.
All models are each 6 kg max.
2 slots:198.5
3 slots: 260
5 slots: 330
Conforms to UL, CSA, cULus, cUL, NK, Lloyd’s, and EC directives.
2
, 3 times each in X, Y, and Z directions According to JIS C0041 / IEC 60068-2-27
130
130
157
C200HW-PA204S
0.625 A, 26 V DC or
0.8 A, 24 V DC
Total: 30 W
24 V DC load current
consumption
Less than 0.3 A: +17%/
–11%
0.3 A or greater: +10%/
–11%
(Lot No. 0197 or higher)
123 (W x H x D) 10 slots:505
123 (W x H x D)
123 (W x H x D) 8 slots: 435
C200HW-PA204R
0.625 A, 24 V DC
Total: 30 W
Not provided
Contact configuration:
SPST-NO
Switch capacity:
250 V AC, 2 A (resis-
tive load)
250 V AC, 0.5 A (induc-
tion load), 24 V DC, 2 A
2
130
in X, Y, and Z directions for 20 minutes. According to JIS C0040 / IEC 60068-2-6
130
123 (W x H x D)
123 (W x H x D)
C200HW-PA209R
180 VA max.
30 A max./100 to 120
V AC
40 A max./200 to 240
V AC
9 A, 5 V DC (including
CPU Unit power)
1.3 A, 26 V DC
Total: 45 W
Contact configuration:
SPST-NO
Switch capacity:
240 V AC, 2 A (resis-
tive load)
120 V AC, 0.5 A (in-
ductive load)
24 V DC, 2 A (resis-
tive load)
24 V DC, 2 A (induc-
tive load)
2
in X, Y, and Z directions for 80 minutes
C200HW-PD024
24 V DC
19.2 to 28.8 V DC
40 W max.
30 A max.
4.6 A, 5 V DC (in-
cluding CPU Unit
power)
0.625 A, 26 V DC
Total: 30 W
Not provided
Not provided
20 M min. (at 500 V DC) between DC ex-
ternal and GR terminals (See Note 1.)
1,000 V AC 50/
60 Hz for 1 min be-
tween DC external
and GR terminals,
leakage current: 10
mA max. (See Note
1.)
Programmable Controllers
C200HW-PD106R
100 V DC
85 to 143 V DC
50 W max.
6 A, 5 V DC (including
CPU Unit power)
1 A, 26 V DC
Total: 30 W
Contact configuration:
SPST-NO
Switch capacity:
250 V AC, 2 A (resis-
tive load)
250 V AC, 0.5 A (in-
duction load), 24 V
DC, 2 A
2,300 V AC 50/60 Hz
for 1 min between AC
external and GR ter-
minals (See Note 1.)
Leakage current: 10
mA max.
cULus