Note: 1. Operation cycles of 0.01, 0.02, and 0.05 s cannot be set for the CS1D-LCB05D.
Loop Control Unit
Item
Model numbers
Operation method
Operation cycle
Number
of function blocks
Method for creating and transfering
function blocks
Control methods
Alarms
Functional Specifications
2. Control blocks such as those for PID control.
3. Operation blocks for process control such as those for alarms, square roots, time/date calculations, and pulse-train computations.
Analog
operation
Sequence control
I/O blocks
System common blocks
PID control method
Control combinations
PID block internal alarms
Alarm blocks
Control blocks
(See note 2.)
Operation blocks
(See note 3.)
External controller
blocks
Sequence tables
Step ladder program
blocks
Field terminal blocks 80 blocks max.
User link
tables
All data
CPU terminal blocks None
Node terminal blocks None
Specifications
CS1W-LCB01
Function block method
Settable cycles:
0.01, 0.02, 0.05, 0.1, 0.2, 0.5, 1, or 2 s(default: 1 s)
Can be set for each function block. (See note 1.)
50 blocks max.
32 blocks max. (CS1D-LCB05D not included)
None
20 blocks max.
2,000 commands total
100 commands max. per block
Separable into a 100 steps max.
2,400 data items max.
HMI functions
2,040 words max.
Allocated 1 EM Area bank
1 block max.
Created and transferred using CX-Process Tool (purchased separately).
PID with 2 degrees of freedom (with auto-tuning)
Any of the following function blocks can be combined:
Basic PID control, cascade control, feed-forward control, sample PI control, Smith dead time compen-
sation control,
PID control with differential gap, override control, program control, time-proportional control, etc.
4 PV alarms (upper upper-limit, upper limit, lower limit, lower lower-limit) and 1 deviation alarm
per PID block
High/low alarm blocks, deviation alarm blocks
CS1W-LCB05
CS1D-LCB05D
500 blocks max.
200 tables max.
32 conditions and 32 actions per
table max. (expandable to 64
conditions and 64 actions per ta-
ble)
6,400 rules total max.
200 blocks max.
4,000 commands total
100 commands max. per block
Seperable into a 100 steps max.
HMI functions
20,040 words max.
Allocated 1 EM Area bank
CS1W-LC001
Settable cycles:
0.1, 0.2, 0.5, 1, or 2 s (default: 1
s)
Can be set for each function
block.
32 blocks max.
249 blocks max.
None
None
Send/Receive All Blocks:
1 block each max.
16 blocks max.
1000 blocks max.
325