CS1W-CN224 Omron, CS1W-CN224 Datasheet - Page 114

no-image

CS1W-CN224

Manufacturer Part Number
CS1W-CN224
Description
"CABLE,CS1/C200H PRO27,2m"
Manufacturer
Omron
Datasheets

Specifications of CS1W-CN224

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Note: Lot numbers for the CS1W-CLK12-V1 and CS1W-CLK52-V1 are 030602 or later (June 2003 or later).
Main Specifications Related to Version Upgrade for Unit Ver. 1.2
Note: CX-Programmer Ver. 5.0 or higher is requested to set a data link area with a maximum number of send and receive words of 20,000 words
Specifications for Networks Using Repeaters
Note: 1. Specifications for each segment are the same as for Wired Controller Link networks.
360
Unit/Board
Controller Link Units
Controller Link Support
Boards
Controller Link Repeater
Units
Item
Number of data link words
Data Link Area allocations User-set allocations
Maximum number of Controller Link Units connected
to a single CPU Unit
Item
Transmission path configuration
Baud rate/maximum transmission distance
(See note 2.)
Maximum number of nodes
Maximum number of Repeater levels (See note 3.)
Specifications
per Controller Unit, or to allocate the same area for Area 1 and Area 2.
2. Maximum transmission distance: Total wired cable length between the two nodes separated by the longest total wired cable length.
3. Maximum number of Repeater levels: Maximum number of Repeaters in a path linking any two nodes. For optical ring types, one set of
two Units comprises one level.
Classification
CPU Bus Unit
Personal computer board
(for PCI bus)
---
Automatically set
equal allocations
Automatically set
1: N allocations
Compatible PLC
CS Series
---
Not mounted to PLC
Unit Ver. 1.2 or later
Number of send/receive words per Unit
Total of Area 1 and Area 2: 20,000 words max.
Number of send words per Unit Total of Area 1 and Area 2: 1,000 words max.
Areas 1 and 2: CIO Area (including data link words), DM Area, and EM Area
Area 1: CIO Area (including data link words), Area 2: DM Area and EM Area
Areas 1 and 2: CIO Area (including data link words), DM Area, and EM Area
8 Units max.
Segment (See note 1.)
Multi-drop
2 Mbps: 500 m
1 Mbps: 800 m
500 kbps: 1 km
Controller Link Unit + Repeater Unit
Total number of nodes: 32
---
Media
Wired
Optical ring
(H-PCF cable)
Optical ring
(GI cable)
Wired
Optical ring
(H-PCF cable)
Optical ring
(GI cable)
Twisted-pair cable
Optical ring
(H-PCF cable)
Optical ring
(GI cable)
Model
CS1W-CLK21-V1
CS1W-CLK12-V1
(See note.)
CS1W-CLK52-V1
(See note.)
3G8F7-CLK21-EV1
3G8F7-CLK12-EV1
3G8F7-CLK52-EV1
CS1W-RPT01
CS1W-RPT02
CS1W-RPT03
Pre-Ver. 1.2
Number of send/receive words per Unit
Total of Area 1 and Area 2: 12,000 words max.
4 Units max.
Total network
Tree (using Repeaters to connect each segment)
2 Mbps: 1.5 km
1 Mbps: 2.4 km
400 kbps: 3.0 km
Controller Link Unit: 62 nodes (using a Controller Link
Unit htat supports 62 nodes)
2 levels
Programmable Controllers
Connections
Can be mounted together
with previous Controller
Link Units/Support Boards.
Unit mounted indepen-
dently using either
DIN Track or screws.

Related parts for CS1W-CN224