Specifications of CS1W-CN224

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Specifications - Duplex Power Supply Units
CS1-series
Item
Power Supply Unit
Supply voltage
Operating voltage range
Power consumption
Inrush current
Output capacity
Output terminal
RUN output
(See Note 2.)
Insulation resistance
Dielectric strength
Noise immunity
Vibration resistance
Shock resistance
Ambient operating tempera-
ture
Ambient operating humidity 10% to 90% (with no condensation)
Atmosphere
Ambient storage tempera-
ture
Grounding
Enclosure
Weight
Specifications
CS1D-PA207R
100 to 120 V AC or 200 to 240 V AC, 50/60 Hz
85 to 132 V AC or 170 to 264 V AC
150 VA max.
30 A max./100 to 120 V AC
40 A max./200 to 240 V AC
7 A, 5 V DC (including CPU Unit power)
1.3 A, 26 V DC
Total: 35 W
Not provided
Contact configuration: SPST-NO
Switch capacity:
240 V AC, 2 A (resistive load)
120 V AC, 0.5 A (inductive load)
24 V DC, 2 A (resistive load)
24 V DC, 2 A (inductive load)
20 M min. (at 500 V DC) between AC external and GR terminals
(See Note 2.)
2,300 V AC 50/60 Hz for 1 min between AC external and GR ter-
minals (See Note 2.)
Leakage current: 10 mA max.
1,000 V AC 50/60 Hz for 1 min between AC external and GR ter-
minals (See Note 1.)
Leakage current: 10 mA max.
Conforms to IEC61000-4-4, 2 kV (power lines)
10 to 57 Hz, 0.075-mm amplitude, 57 to 150 Hz, acceleration: 9.8 m/s
(Sweep time 8 min 10 = total time 80 min.)
CPU Unit mounted to a DIN rail: 2 to 55 Hz, 2.9 m/s
147 m/s
0 to 55 C
Must be free from corrosive gases.
–20 to 75 C (excluding battery)
Less than 100
Mounted in a panel.
All models are each 6 kg max.
2
, 3 times each in X, Y, and Z directions According to JIS C0041 / IEC 60068-2-27
2
in X, Y, and Z directions for 20 minutes. According to JIS C0040 / IEC 60068-2-6
CS1D-PD024
30 A max.
0.56 A, 26 V DC
Total: 28 W
Not provided
20 M min. (at 500 V DC) between DC external and GR terminals
24 V DC
19.2 to 28.8 V DC
40 W max.
4.3 A, 5 V DC (including CPU Unit power)
Not provided
(See Note 2.)
1,000 V AC 50/60 Hz for 1 min between DC external and GR termi-
nals, leakage current: 10 mA max. (See Note 2.)
2
in X, Y, and Z directions for 80 minutes
279