BCM5208KPF Broadcom, BCM5208KPF Datasheet - Page 34

BCM5208KPF

Manufacturer Part Number
BCM5208KPF
Description
Manufacturer
Broadcom
Datasheet

Specifications of BCM5208KPF

Number Of Receivers
4
Data Rate
10/100Mbps
Operating Temperature Classification
Commercial
Operating Supply Voltage (min)
3.14V
Mounting
Surface Mount
Operating Temperature (max)
70C
Operating Temperature (min)
0C
Lead Free Status / RoHS Status
Not Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
BCM5208KPF
Manufacturer:
ON
Quantity:
201
Part Number:
BCM5208KPF
Quantity:
5 510
Part Number:
BCM5208KPF
Manufacturer:
BCM
Quantity:
846
Part Number:
BCM5208KPF
Manufacturer:
BROADCOM
Quantity:
1 000
Part Number:
BCM5208KPF
Manufacturer:
BROADCOM
Quantity:
1 000
Part Number:
BCM5208KPF
Manufacturer:
BROADCOM
Quantity:
1 000
Part Number:
BCM5208KPF
Manufacturer:
BROADCOM
Quantity:
1 000
Part Number:
BCM5208KPF
Manufacturer:
BROADCOM
Quantity:
1 000
Part Number:
BCM5208KPF
Manufacturer:
BROADCOM
Quantity:
20 000
n BCM5208
BAD ESD DETECTED. The PHY will return a “1” in bit 4 if an end of stream delimiter error has been detected since the
last time this register was read. Otherwise it will return a “0”.
RECEIVE ERROR DETECTED. The PHY will return a “1” in bit 3 if a packet was received with an invalid code since the
last time this register was read. Otherwise it will return a “0”.
TRANSMIT ERROR DETECTED. The PHY will return a “1” in bit 2 if a packet was received with a transmit error code since
the last time this register was read. Otherwise it will return a “0”.
LOCK ERROR DETECTED. The PHY will return a “1” in bit 1 if the de-scrambler has lost lock since the last time this
register was read. Otherwise it will return a “0”.
MLT3 CODE ERROR DETECTED. The PHY will return a “1” in bit “0” if an MLT3 coding error has been detected in the
receive data stream since the last time this register was read. Otherwise it will return a “0”. ..
100BASE-X RECEIVE ERROR COUNTER
The 100BASE-X receive error counter will increment each time the BCM5208 receives a non-collision packet containing
at least one receive error. The counter will automatically clear itself when read. When the counter reaches its maximum
value, FFh, it stops counting Receive Errors until cleared. See Table 16 for the bit descriptions.
100BASE-X FALSE CARRIER SENSE COUNTER
The 100BASE-X false carrier sense counter will increment each time the BCM5208 detects a false carrier on the receive
input. The counter will automatically clear itself when read. When the counter reaches its maximum value, FFh, it stops
counting False Carrier Sense Errors until cleared. See Table 17 for the bit descriptions.
100BASE-X DISCONNECT COUNTER
The 100BASE-X disconnect counter will increment each time the carrier integrity monitor within the BCM5208 enters the
“link unstable” state. The counter will automatically clear itself when read. When the counter reaches its maximum value,
FFh, it stops counting Disconnects until cleared. See Table 18 for the bit descriptions.
Page 26
BIT
15:8
7:0
BIT
15:8
7:0
BIT
15:8
7:0
NAME
Reserved
False Carrier Sense Counter
NAME
Reserved
Receive Error Counter
NAME
Reserved
Disconnect Counter
Table 17: 100BASE-X False Carrier Sense Counter (Address 19d, 13h)
Table 16: 100BASE
Table 18: 100BASE-X Disconnect Counter (Address 20d, 14h)
R/W
RO
R/W
-X
R/W
RO
R/W
R/W
RO
R/W
B r o a d c o m C o r p o r a t i o n
Receive Error Counter (Address 18d, 012h)
DESCRIPTION
Write as 0, Ignore when Read
Number of False Carrier Sense events since last Read 00h
DESCRIPTION
Write as 0; Ignore when Read
Number of Non-Collision packets with Receive
Errors since last Read
DESCRIPTION
Write as 0, Ignore when Read
Number of Disconnects since last Read
Document 5208-DS03-R¥¥¥¥¥
November 3, 1999
DEFAULT
00h
DEFAULT
DEFAULT
00h

Related parts for BCM5208KPF