EP2SGX60EF1152C3N Altera, EP2SGX60EF1152C3N Datasheet - Page 23

IC STRATIX II GX 60K 1152-FBGA

EP2SGX60EF1152C3N

Manufacturer Part Number
EP2SGX60EF1152C3N
Description
IC STRATIX II GX 60K 1152-FBGA
Manufacturer
Altera
Series
Stratix® II GXr
Datasheet

Specifications of EP2SGX60EF1152C3N

Number Of Logic Elements/cells
60440
Number Of Labs/clbs
3022
Total Ram Bits
2544192
Number Of I /o
534
Voltage - Supply
1.15 V ~ 1.25 V
Mounting Type
Surface Mount
Operating Temperature
0°C ~ 85°C
Package / Case
1152-FBGA
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Number Of Gates
-
Other names
544-2181

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
EP2SGX60EF1152C3N
Manufacturer:
ATMEL
Quantity:
1 420
Part Number:
EP2SGX60EF1152C3N
Manufacturer:
Altera
Quantity:
10 000
Part Number:
EP2SGX60EF1152C3N
Manufacturer:
ALTERA
0
Part Number:
EP2SGX60EF1152C3N
Manufacturer:
ALTERA
Quantity:
300
Part Number:
EP2SGX60EF1152C3N
0
Altera Corporation
October 2007
Receiver Input Buffer
The Stratix II GX receiver input buffer supports the 1.2-V and 1.5-V
PCML I/O standard at rates up to 6.375 Gbps. The common mode voltage
of the receiver input buffer is programmable between 0.85 V and 1.2 V.
You must select the 0.85 V common mode voltage for AC- and
DC-coupled PCML links and the 1.2 V common mode voltage for
DC-coupled LVDS links.
The receiver has programmable on-chip 100-, 120-, or 150-Ω differential
termination for different protocols, as shown in
receiver’s internal termination can be disabled if external terminations
and biasing are provided. The receiver and transmitter differential
termination resistances can be set independently of each other.
Figure 2–12. Receiver Input Buffer
Programmable Termination
The programmable termination can be statically set in the Quartus II
software.
termination. The termination can be disabled if external termination is
provided.
Input
Pins
Lane deskew
Rate matcher
8B/10B decoder
Byte deserializer
Byte ordering
Receiver phase compensation FIFO buffer
Figure 2–13
Programmable
Termination
shows the setup for programmable receiver
Stratix II GX Device Handbook, Volume 1
Programmable
Equalizer
Figure
Stratix II GX Architecture
2–12. The
Differential
Buffer
Input
2–15

Related parts for EP2SGX60EF1152C3N