EP4CE55F23C6N Altera, EP4CE55F23C6N Datasheet - Page 407

no-image

EP4CE55F23C6N

Manufacturer Part Number
EP4CE55F23C6N
Description
IC CYCLONE IV FPGA 55K 484FBGA
Manufacturer
Altera
Series
CYCLONE® IV Er

Specifications of EP4CE55F23C6N

Number Of Logic Elements/cells
55856
Number Of Labs/clbs
3491
Total Ram Bits
2340000
Number Of I /o
324
Voltage - Supply
1.15 V ~ 1.25 V
Mounting Type
Surface Mount
Operating Temperature
0°C ~ 85°C
Package / Case
484-FBGA
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Number Of Gates
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
EP4CE55F23C6N
Manufacturer:
ALTERA
Quantity:
648
Part Number:
EP4CE55F23C6N
Manufacturer:
Altera
Quantity:
10 000
Part Number:
EP4CE55F23C6N
Manufacturer:
ALTERA
0
Part Number:
EP4CE55F23C6N
Manufacturer:
ALTERA/阿尔特拉
Quantity:
20 000
Part Number:
EP4CE55F23C6N
0
Company:
Part Number:
EP4CE55F23C6N
Quantity:
240
Chapter 3: Cyclone IV Dynamic Reconfiguration
Dynamic Reconfiguration Modes
© December 2010 Altera Corporation
Method 3: Writing Different Control Signals for all the Transceiver Channels at the
Same Time
If you disable the Use the same control signal for all the channels option, the PMA
control ports for a write transaction are separate for each channel. If you disable this
option, the width of the PMA control ports are fixed as follows:
PMA Control Ports Used in a Write Transaction
For example, if you have two channels, the tx_vodctrl is 6 bits wide
(tx_vodctrl [2:0] corresponds to channel 1 and tx_vodctrl [5:3] corresponds to
channel 2).
PMA Control Ports Used in a Read Transaction
The width of the PMA control ports for a read transaction are always separate for each
channel as explained in
the Transceiver Channels” on page
Write Transaction
Because the PMA controls of all the channels are written, if you want to reconfigure a
specific channel connected to the ALTGX_RECONFIG instance, set the new value at
the corresponding PMA control port of the channel under consideration and retain
the previously stored values in the other active channels with a read transaction prior
to this write transaction.
For example, if the number of channels controlled by the ALTGX_RECONFIG
instance is two, the tx_vodctrl signal in this case would be 6 bits wide. The
tx_vodctrl[2:0] signal corresponds to channel 1 and the tx_vodctrl[5:3] signal
corresponds to channel 2.
tx_vodctrl is 3 bits per channel
tx_preemp are 5 bits per channel
rx_eqdcgain is 2 bits per channel
rx_eqctrl is 4 bits per channel
To dynamically reconfigure the PMA controls of only channel 2 with a new value,
first perform a read transaction to retrieve the existing PMA control values from
tx_vodctrl_out[5:0]. Use the tx_vodctrl_out[2:0] value for tx_vodctrl[2:0]
to write in channel 1. By doing so, channel 1 is overwritten with the same value.
Perform a write transaction. This ensures that the new values are written only to
channel 2 while channel 1 remains unchanged.
“Method 2: Writing the Same Control Signals to Control All
3–14.
Cyclone IV Device Handbook, Volume 2
3–17

Related parts for EP4CE55F23C6N