TMP89xy60UG/FG Toshiba, TMP89xy60UG/FG Datasheet - Page 272

no-image

TMP89xy60UG/FG

Manufacturer Part Number
TMP89xy60UG/FG
Description
Manufacturer
Toshiba
Datasheet

Specifications of TMP89xy60UG/FG

Package
LQFP64/QFP64
Rom Types (m=mask,p=otp,f=flash)
M/F
Rom Size
32/60
Ram Size
3K
Driver Led
8
Driver Lcd
-
Spi/sio Channels
-
Uart/sio Channels
2
I2c/sio Channels
1
High-speed Serial Output
-
Adc 8-bit Channels
-
Adc 10-bit Channels
16
Da Converter Channels
-
Timer Counter 18-bit Channel
-
Timer Counter 16-bit Channel
2
Timer Counter 8-bit Channel
4
Motor Channels
-
Watchdog Timer
Y
Dual Clock
Y
Clock Gear
Y
Number Of I/o Ports
58
Power Supply (v)
4.3 to 5.5
17.5
Transfer Modes
RA001
17.5.1.5
operation is not in progress, the transmit operation is stopped immediately and an INTSIO0 interrupt request
is generated. When SIO0SR<SEF> is "1", the transmit operation is stopped after all the data in the shift register
is transmitted (reserved stop). At this time, an INTSIO0 interrupt request is generated again.
SIO0SR registers keep their values.
has been used, the SO0 pin keeps the last output value. To return the SO0 pin to the "H" level, write "00" to
SIO0CR<SIOM> when the operation is stopped.
setting SIO0CR<SIOM> to "00", SIO0CR<SIOS> and SIO0SR are cleared to "0" and the SIO stops the
operation, regardless of the SIO0SR<SEF> value. The SO0 pin becomes the "H" level. If the internal clock
is selected, the SCLK0 pin returns to the initial level.
(2)
(3)
Set SIO0CR<SIOS> to "0" to stop the transmit operation. When SIO0SR<SEF> is "0", or when the shift
When the transmit operation is completed, SIO0SR<SIOF, SEF and TBFL> are cleared to "0". Other
If the internal clock has been used, the SO0 pin automatically returns to the "H" level. If an external clock
The transmit operation can be forced to stop by setting SIO0CR<SIOM> to "00" during the operation. By
Stopping the transmit operation
outputs the serial clock, and the transmit operation is restarted. An INTSIO0 interrupt request is gen-
erated at the restart of the transmit operation.
clock is input to the SCLK0 pin after completion of the data transmission, an undefined value is trans-
mitted and the transmit underrun error flag SIO0SR<UERR> is set to "1".
an undefined value. (It is recommended to finish the transmit operation by setting SIO0CR<SIOS> to
"0" or force the transmit operation to stop by setting SIO0CR<SIOM> to "00".)
is transferred to the shift register and the transmission of subsequent data is started. At this time,
SIO0SR<SEF> is set to "1" and an INTSIO0 interrupt request is generated.
When the subsequent data is written into SIO0BUF, SIO0SR<SEF> is set to "1", the SCLK0 pin
When the data transmission is completed, the SO pin keeps last output value. When an external serial
If a transmit underrun error occurs, data must not be written to SIO0BUF during the transmission of
The transmit underrun error flag SIO0SR<UERR> is cleared by reading SIO0SR.
When the data transmission is completed, SIO0SR<TBFL> is cleared to "0". The data in SIO0BUF
When an external clock is used and SIO0SR<TBFL> is "0"
When an internal or external clock is used and SIO0SR<TBFL> is "1"
Page 256
TMP89FS60

Related parts for TMP89xy60UG/FG