Descrambler Key Initialization Register - Address 16h
DS206TPP2
15
14:11 Reserved
10:0
CS8952T
CrystalLAN™ 100BASE-X and 10BASE-T Transceiver
BIT
Load
15
7
Load
Descrambler Initial-
ization Key
NAME
14
6
Read/Set
Read Only
Read/Write Reset value is
CIRRUS LOGIC ADVANCED PRODUCT DATABOOK
TYPE
13
5
Reserved
0
0000
dependent on the
PHY Address field
of the Self Status
Register (address
19h).
Descrambler Initialization Key
RESET
12
4
When this bit is set, the descrambler will be loaded
with the value in the Descrambler Initialization Key
field. When the load is complete, this bit will clear
automatically.
These bits should be read as don’t cares and, when
written, should be written to 0.
This register allows the Descrambler to be loaded
with a user-definable key sequence. A value of 000h
has the effect of bypassing the descrambler function.
This is valuable for testing purposes to allow a deter-
ministic response to test stimulus without a synchro-
nization delay.
Note: This field is disabled, and writes to this bit are
ignored when the National Compatibility Mode bit of
the 10BASE-T Configuration Register (address 1Ch)
is set.
11
3
10
2
Descrambler Initialization Key
DESCRIPTION
9
1
8
0
51