M58WR064 STMICROELECTRONICS [STMicroelectronics], M58WR064 Datasheet - Page 78

no-image

M58WR064

Manufacturer Part Number
M58WR064
Description
64 Mbit 4Mb x 16, Multiple Bank, Burst 1.8V Supply Flash Memory
Manufacturer
STMICROELECTRONICS [STMicroelectronics]
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
M58WR064
Manufacturer:
ST
Quantity:
10 850
Part Number:
M58WR064
Manufacturer:
ST
0
Part Number:
M58WR064-FU70ZB6S
Manufacturer:
ST
Quantity:
125
Part Number:
M58WR064-FU70ZB6S
Manufacturer:
SIEMENS
Quantity:
412
Part Number:
M58WR064-FU70ZB6S
Manufacturer:
ST
0
Part Number:
M58WR064EB70ZB6
Manufacturer:
Micron Technology Inc
Quantity:
10 000
Part Number:
M58WR064EB70ZB6
Manufacturer:
ST
0
Part Number:
M58WR064EB70ZB6T
Manufacturer:
STMicroelectronics
Quantity:
10 000
Part Number:
M58WR064FP70ZB6
Manufacturer:
ROHM
Quantity:
6 259
Part Number:
M58WR064FP70ZB6
Manufacturer:
ST
Quantity:
20 000
Part Number:
M58WR064FU70
Manufacturer:
SHARP
Quantity:
1
M58WR064ET, M58WR064EB
Table 41. Command Interface States - Modify Table, Next Output
Note: 1. CI = Command Interface, CR = Configuration Register, EFP = Enhanced Factory Program, Quad EFP = Quadruple Enhanced Fac-
78/82
Quad EFP Setup
Current CI State
Quad EFP Busy
Program Setup
Erase Suspend
Lock/CR Setup
Lock/CR Setup
Program/Erase
Erase Suspend
Erase Suspend
Program Busy
Erase Setup
Erase Busy
Suspended
Program in
Program in
Program in
OTP Setup
EFP Setup
EFP Verify
EFP Busy
OTP Busy
Suspend
in Erase
Ready
2. At Power-Up, all banks are in Read Array mode. A Read Array command issued to a busy bank, results in undetermined data out-
3. The two cycle command should be issued to the same bank address.
4. If the P/E.C. is active, both cycles are ignored.
5. The Clear Status Register command clears the Status Register error bits except when the P/E.C. is busy or suspended.
6. The output state shows the type of data that appears at the outputs if the bank address is the same as the command address. A
Busy
tory Program, DWP = Double Word Program, QWP = Quadruple Word Program, P/E. C. = Program/Erase Controller.
put.
bank can be placed in Read Array, Read Status Register, Read Electronic Signature or Read CFI Query mode, depending on the
command issued. Each bank remains in its last output state until a new command is issued. The next state does not depend on the
bank’s output state.
Array
Read
Array
Array
(2)
Program
Setup
DWP,
QWP
(3,4)
Erase,
Setup
Block
Erase
Bank
Status Register
Status Register
(3,4)
Setup
Next Output State After Command Input (6)
EFP
Quad-
Setup
EFP
Status Register
Status Register
Resume,
confirm,
Confirm
Confirm
Unlock
Output Unchanged
Output Unchanged
Erase
Block
EFP
P/E
Program/
Suspend
Erase
Register
Register
Register
Status
Status
Status
Read
Clear status
Unchanged
Unchanged
Register
Output
Output
(5)
Electronic
signature,
Signature/
Electronic
Read CFI
Register
Query
Status
Read
CFI

Related parts for M58WR064