S9S12GN16F0CFT Freescale Semiconductor, S9S12GN16F0CFT Datasheet - Page 377

no-image

S9S12GN16F0CFT

Manufacturer Part Number
S9S12GN16F0CFT
Description
16-bit Microcontrollers - MCU 16-bit16k Flash 2k RAM
Manufacturer
Freescale Semiconductor
Datasheet

Specifications of S9S12GN16F0CFT

Rohs
yes
Core
S12
Processor Series
MC9S12G
Data Bus Width
16 bit
Maximum Clock Frequency
25 MHz
Program Memory Size
16 KB
Data Ram Size
1024 B
On-chip Adc
Yes
Operating Supply Voltage
3.13 V to 5.5 V
Operating Temperature Range
- 40 C to + 85 C
Package / Case
TSSOP-20
Mounting Style
SMD/SMT
Freescale Semiconductor
OSCSEL1
PLLSEL
PSTP
Field
COP
PRE
PCE
7
6
4
3
2
PLL Select Bit
This bit selects the PLLCLK as source of the System Clocks (Core Clock and Bus Clock).
PLLSEL can only be set to 0, if UPOSC=1.
UPOSC= 0 sets the PLLSEL bit.
Entering Full Stop Mode sets the PLLSEL bit.
0 System clocks are derived from OSCCLK if oscillator is up (UPOSC=1, f
1 System clocks are derived from PLLCLK, f
Pseudo Stop Bit
This bit controls the functionality of the oscillator during Stop Mode.
0 Oscillator is disabled in Stop Mode (Full Stop Mode).
1 Oscillator continues to run in Stop Mode (Pseudo Stop Mode), option to run RTI and COP.
Note: Pseudo Stop Mode allows for faster STOP recovery and reduces the mechanical stress and aging of the
Note: When starting up the external oscillator (either by programming OSCE bit to 1 or on exit from Full Stop
COP Clock Select 1 — COPOSCSEL0 and COPOSCSEL1 combined determine the clock source to the COP
(see also
If COPOSCSEL1 = 1, COPOSCSEL0 has no effect regarding clock select and changing the COPOSCSEL0 bit
does not re-start the COP time-out period.
COPOSCSEL1 selects the clock source to the COP to be either ACLK (derived from trimmable internal
RC-Oscillator) or clock selected via COPOSCSEL0 (IRCCLK or OSCCLK
Changing the COPOSCSEL1 bit re-starts the COP time-out period.
COPOSCSEL1 can be set independent from value of UPOSC.
UPOSC= 0 does not clear the COPOSCSEL1 bit.
0 COP clock source defined by COPOSCSEL0
1 COP clock source is ACLK derived from a trimmable internal RC-Oscillator
RTI Enable During Pseudo Stop Bit — PRE enables the RTI during Pseudo Stop Mode.
0 RTI stops running during Pseudo Stop Mode.
1 RTI continues running during Pseudo Stop Mode if RTIOSCSEL=1.
Note: If PRE=0 or RTIOSCSEL=0 then the RTI will go static while Stop Mode is active. The RTI counter will not
COP Enable During Pseudo Stop Bit — PCE enables the COP during Pseudo Stop Mode.
0 COP stops running during Pseudo Stop Mode if: COPOSCSEL1=0 and COPOSCSEL0=0
1 COP continues running during Pseudo Stop Mode if: PSTP=1, COPOSCSEL1=0 and COPOSCSEL0=1
Note: If PCE=0 or COPOSCSEL0=0 while COPOSCSEL1=0 then the COP is static during Stop Mode being
resonator in case of frequent STOP conditions at the expense of a slightly increased power consumption.
Mode with OSCE bit is already 1) the software must wait for a minimum time equivalent to the startup-time
of the external oscillator t
be reset.
active. The COP counter will not be reset.
Table
10-6).
MC9S12G Family Reference Manual, Rev.1.23
Table 10-5. CPMUCLKS Descriptions
UPOSC
before entering Pseudo Stop Mode.
bus
= f
Description
PLL
/ 2.
S12 Clock, Reset and Power Management Unit (S12CPMU)
)
.
bus
= f
osc
/ 2.