AT32UC3L064-AUT Atmel, AT32UC3L064-AUT Datasheet - Page 363

MCU AVR32 64KB FLASH 48TQFP

AT32UC3L064-AUT

Manufacturer Part Number
AT32UC3L064-AUT
Description
MCU AVR32 64KB FLASH 48TQFP
Manufacturer
Atmel
Series
AVR®32 UC3r

Specifications of AT32UC3L064-AUT

Core Processor
AVR
Core Size
32-Bit
Speed
50MHz
Connectivity
I²C, SPI, UART/USART
Peripherals
Brown-out Detect/Reset, DMA, PWM, WDT
Number Of I /o
36
Program Memory Size
64KB (64K x 8)
Program Memory Type
FLASH
Ram Size
16K x 8
Voltage - Supply (vcc/vdd)
1.62 V ~ 3.6 V
Data Converters
A/D 9x10b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
48-TQFP, 48-VQFP
Processor Series
AT32UC3x
Core
AVR32
Data Bus Width
32 bit
Data Ram Size
16 KB
Interface Type
SPI/TWI/USART
Maximum Clock Frequency
50 MHz
Number Of Programmable I/os
36
Number Of Timers
7
Maximum Operating Temperature
+ 85 C
Mounting Style
SMD/SMT
3rd Party Development Tools
EWAVR32, EWAVR32-BL
Development Tools By Supplier
AT32UC3L-EK
Minimum Operating Temperature
- 40 C
On-chip Adc
9-ch x 10-bit
Package
48TQFP
Device Core
AVR32
Family Name
AT32
Maximum Speed
50 MHz
Operating Supply Voltage
1.8|3.3 V
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AT32UC3L064-AUT
Manufacturer:
HONGFA
Quantity:
30 000
Part Number:
AT32UC3L064-AUT
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
AT32UC3L064-AUT
Manufacturer:
MICROCHIP/微芯
Quantity:
20 000
19.6.1.2
Table 19-3.
19.6.1.3
32099F–11/2010
Source Clock
12 000 000
12 288 000
14 318 180
14 745 600
18 432 000
24 000 000
24 576 000
25 000 000
32 000 000
32 768 000
33 000 000
40 000 000
50 000 000
60 000 000
3 686 400
4 915 200
5 000 000
7 372 800
8 000 000
MHz
Baud Rate Calculation Example
Fractional Baud Rate in Asynchronous Mode
Baud Rate Example (OVER = 0)
Expected Baud
Table 19-3
clock frequencies. This table also shows the actual resulting baud rate and the error.
The baud rate is calculated with the following formula:
The baud rate error is calculated with the following formula. It is not recommended to work with
an error higher than 5%.
The Baud Rate generator previously defined is subject to the following limitation: the output fre-
quency changes by only integer multiples of the reference frequency. An approach to this
problem is to integrate a fractional N clock generator that has a high resolution. The generator
architecture is modified to obtain Baud Rate changes by a fraction of the reference source clock.
This fractional part is programmed with the FP field in the Baud Rate Generator Register
38 400
38 400
38 400
38 400
38 400
38 400
38 400
38 400
38 400
38 400
38 400
38 400
38 400
38 400
38 400
38 400
38 400
38 400
38 400
Rate
Bit/s
Error
BaudRate
shows calculations of CD to obtain a baud rate at 38400 bauds for different source
=
1
Calculation Result
ExpectedBaudRate
-------------------------------------------------- -
ActualBaudRate
=
(
12.00
13.02
19.53
20.00
23.30
24.00
30.00
39.06
40.00
40.69
52.08
53.33
53.71
65.10
81.38
97.66
6.00
8.00
8.14
CLKUSART
)
(
CD
CD
12
13
20
20
23
24
30
39
40
40
52
53
54
65
81
98
×
6
8
8
16
)
Actual Baud Rate
AT32UC3L016/32/64
38 400.00
38 400.00
39 062.50
38 400.00
38 461.54
37 500.00
38 400.00
38 908.10
38 400.00
38 400.00
38 461.54
38 400.00
38 109.76
38 461.54
38 641.51
38 194.44
38 461.54
38 580.25
38 265.31
Bit/s
0.00%
0.00%
1.70%
0.00%
0.16%
2.40%
0.00%
1.31%
0.00%
0.00%
0.16%
0.00%
0.76%
0.16%
0.63%
0.54%
0.16%
0.47%
0.35%
Error