DP83848VYB National Semiconductor, DP83848VYB Datasheet - Page 54

TRANSCEIVER, ENET PHY, 10/100, 48LQFP

DP83848VYB

Manufacturer Part Number
DP83848VYB
Description
TRANSCEIVER, ENET PHY, 10/100, 48LQFP
Manufacturer
National Semiconductor
Datasheet

Specifications of DP83848VYB

Data Rate
100Mbps
No. Of Ports
1
Ethernet Type
IEEE 802.3u
Supply Current
92mA
Supply Voltage Range
3V To 3.6V
Operating Temperature Range
-40°C To +105°C
Digital Ic Case Style
LQFP
No.
RoHS Compliant
Interface Type
MII Serial, RMII
Rohs Compliant
Yes
Lead Free Status / Rohs Status
Not Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
DP83848VYB/NOPB
Manufacturer:
NS
Quantity:
570
Part Number:
DP83848VYB/NOPB
Manufacturer:
Texas Instruments
Quantity:
10 000
Part Number:
DP83848VYB/NOPB
0
www.national.com
Bit
7:4
3:0
12
11
10
9
8
ED_DATA_COUNT
ED_ERR_COUNT
ED_PWR_STATE
ED_BURST_DIS
ED_DATA_MET
ED_ERR_MET
Bit Name
ED_MAN
0, RO/COR
0, RO/COR
0, RW/SC
0001, RW
0001, RW
Default
0, RW
0, RO
Energy Detect Manual Power Up/Down:
Begin power up/down sequence when this bit is asserted. When set,
the Energy Detect algorithm will initiate a change of Energy Detect state
regardless of threshold (error or data) and timer values. In managed
applications, this bit can be set after clearing the Energy Detect interrupt
to control the timing of changing the power state.
Energy Detect Burst Disable:
Disable bursting of energy detect data pulses. By default, Energy Detect
(ED) transmits a burst of 4 ED data pulses each time the CD is powered
up. When bursting is disabled, only a single ED data pulse will be send
each time the CD is powered up.
Energy Detect Power State:
Indicates current Energy Detect Power state. When set, Energy Detect
is in the powered up state. When cleared, Energy Detect is in the
powered down state. This bit is invalid when Energy Detect is not
enabled.
Energy Detect Error Threshold Met:
No action is automatically taken upon receipt of error events. This bit is
informational only and would be cleared on a read.
Energy Detect Data Threshold Met:
The number of data events that occurred met or surpassed the Energy
Detect Data Threshold. This bit is cleared on a read.
Energy Detect Error Threshold:
Threshold to determine the number of energy detect error events that
should cause the device to take action. Intended to allow averaging of
noise that may be on the line. Counter will reset after approximately 2
seconds without any energy detect data events.
Energy Detect Data Threshold:
Threshold to determine the number of energy detect events that should
cause the device to take actions. Intended to allow averaging of noise
that may be on the line. Counter will reset after approximately 2 seconds
without any energy detect data events.
54
Description