CS1W-CN313 Omron, CS1W-CN313 Datasheet - Page 120

no-image

CS1W-CN313

Manufacturer Part Number
CS1W-CN313
Description
"CABLE CS1 EXP I/O,30cm"
Manufacturer
Omron
Datasheet

Specifications of CS1W-CN313

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Connecting to Peripheral
Port using RS-232C
Cable
Connecting to RS-232C
Port using RS-232C
Cable
98
Programming Devices
CPU Unit
CPU Unit
CPU Unit
Serial
Communications
Board
Unit/Board
Unit
Unit
Peripheral
port
Port
Peripheral port
Built-in
RS-232C port
(D-Sub, 9-pin,
female)
RS-232C port
(D-Sub, 9-pin,
female)
Port
Port
Note The Startup Mode in the above table is for when DM 6600 in the PC Setup is
Note The Startup Modes in the above table are for when DM 6600 in the PC Setup
Note The Startup Mode in the above table is for when DM 6600 in the PC Setup is
Peripheral bus or
Host Link
(SYSMAC WAY)
communications
DM 6600 in the PC Setup is set to the default settings), will be RUN mode as
shown in the following table.
set to the default settings. The Startup Mode depends on the type of cable
used. For details refer to 5-2-3 Startup Mode.
When connecting an RS-232C cable to the peripheral port, use the CS1W-
CN118 Connecting Cable as indicated below. When the XW2Z-200S-CV/
500S-CV is connected, the Startup Mode (when DM 6600 in the PC Setup is
set to the default settings) will be RUN mode.
is set to the default settings. The Startup Mode depends on the type of con-
necting cable used. For details refer to 5-2-3 Startup Mode.
When connecting an IBM PC/AT or compatible computer to the RS-232C port
(built-in or on the Serial Communications Board) using an RS-232C cable, the
following connection methods are possible.
set to the default setting. The Startup Mode depends on the type of connect-
ing cable used. For details refer to 5-2-3 Startup Mode.
Serial
mode
Host Link
(SYSMAC WAY)
communications
Peripheral bus or
Host Link
(SYSMAC WAY)
communications
Serial
mode
Serial
mode
Connecting cables
XW2Z-200S(-V)(-CV) (2 m)
XW2Z-500S(-V)(-CV) (5 m)
CS1W-CN118 +
XW2Z-200S-CV/
500S-CV
CS1W-CN118 +
XW2Z-200S-V/
500S-V
Model number
XW2Z-200S-V
XW2Z-500S-V
XW2Z-200S-V
XW2Z-500S-V
Model number
CS1W-CN226 or
CS1W-CN626
Model number
IBM PC/AT or compatible computer
0.1 m +
(2 m or 5 m)
Length
2 m
5 m
2 m
5 m
CS1W-CN118
Length
2 m or 6 m
CQM1H CPU Unit
Use a connector
for which ESD
countermeasures
have been taken
with the
XW2Z-@@@S-
CV.
---
Length
Comments
---
Comments
Peripheral port
RUN mode
Startup Mode
Ignored
Section 3-6
RUN mode
PROGRAM
mode
Startup Mode
(see note)
Startup Mode
(see note)
(see note)

Related parts for CS1W-CN313