CS1W-CN313 Omron, CS1W-CN313 Datasheet - Page 56

no-image

CS1W-CN313

Manufacturer Part Number
CS1W-CN313
Description
"CABLE CS1 EXP I/O,30cm"
Manufacturer
Omron
Datasheet

Specifications of CS1W-CN313

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
34
Functions Listed by Purpose
Detection sensor
input
Analog sensor input Reading analog voltage
Temperature
control functions
Purpose
Reducing wiring and
space required for
sensor output
or current signals from
sensors or measuring
devices, and outputting
analog signals to
inverters or analog
control devices
Reading distance data
such as level
differences and panel
thicknesses, by using in
combination with
displacement sensors
Reading data from two
temperature controllers
with one Unit
Reading data from two
or four temperature
controllers with one Unit
Sensor Unit
Analog Input Unit
or Analog
Output Unit
(Power Supply
Unit required)
Linear Sensor
Interface Unit
Temperature
Controller Unit
CQM1-TC00@
CQM1-TC10@
Temperature
Controller Unit
CQM1-TC20@
CQM1-TC30@
Unit/Board
Input function for
Optic Fiber
Photoelectric
Module,
Photoelectric
Module with
Separate
Amplifier and
Proximity Module
with Separate
Amplifier
(amplifier function)
Analog I/O
Input/operation
function for data
from linear sensor/
amplifier
Temperature
control function
Function
Up to four Sensor Modules
(amplifier sections) of three kinds
of sensor (fiber photoelectric
sensor, photoelectric sensor with
separable amplifier and proximity
sensor with separable amplifier)
can be mounted to a single
Sensor Unit. Sensor Modules can
be selected and combined
according to the object to be
detected and the distance.
Analog input: 4 points (0 to
20 mA, 0 to 5 V, –10 to +10 V)
Analog output: 2 points (0 to
20 mA, –10 to +10 V)
High-speed, high-precision
measurement of voltage or
current input from linear
(displacement) sensors is
performed and the
measurements are converted to
numeric data for comparative
decision processing. Input can be
held according to external timing
signals.
Sampling cycle: 1 ms; External
timing sampling time: 0.3 ms
Number of loops: 2
Input: Thermocouple (K, J) or
platinum resistance thermometer
(Pt, JPt)
Output: ON/OFF or advanced PID
control (time-proportional) control
Number of loops: 4 or 2 (heater
burnout detection function)
Input: Thermocouple (K, J, L, T,
R, S, B) or platinum resistance
thermometer (Pt, JPt)
Output: ON/OFF or advanced PID
control (time-proportional) control
Details
Section 1-4

Related parts for CS1W-CN313