xvi
Application Precautions
• A ground of 100
• Use crimp terminals for wiring. Do not connect bare stranded wires
• Do not apply voltages to the Input Units in excess of the rated input volt-
• Do not apply voltages or connect loads to the Output Units in excess of
• Install external breakers and take other safety measures against short-cir-
• Always use the power supply voltages specified in the operation manuals.
• Take appropriate measures to ensure that the specified power with the
• Disconnect the functional ground terminal when performing withstand
• Check switch settings, the contents of the DM Area, and other prepara-
• Check the user program for proper execution before actually running it on
• Double-check all wiring and switch settings before turning ON the power
• Confirm that no adverse effect will occur in the system before attempting
• Before touching a Unit, be sure to first touch a grounded metallic object in
• Do not pull on the cables or bend the cables beyond their natural limit.
• Do not place objects on top of the cables or other wiring lines. Doing so
• Resume operation only after transferring to the new CPU Unit the con-
• Do not short the battery terminals or charge, disassemble, heat, or incin-
terminals. The product will be destroyed if 200 to 240 V AC is supplied
while the metal jumper is attached.
terminals on the Power Supply Unit.
directly to terminals. Connection of bare stranded wires may result in
burning.
age. Excess voltages may result in burning.
the maximum switching capacity. Excess voltage or loads may result in
burning.
cuiting in external wiring. Insufficient safety measures against short-cir-
cuiting may result in burning.
An incorrect voltage may result in malfunction or burning.
rated voltage and frequency is supplied. Be particularly careful in places
where the power supply is unstable. An incorrect power supply may result
in malfunction.
voltage tests. Not disconnecting the functional ground terminal may result
in burning.
tions before starting operation. Starting operation without the proper set-
tings or data may result in an unexpected operation.
the Unit. Not checking the program may result in an unexpected opera-
tion.
supply. Incorrect wiring may result in burning.
any of the following. Not doing so may result in an unexpected operation.
order to discharge any static build-up. Not doing so may result in malfunc-
tion or damage.
Doing either of these may break the cables.
may break the cables.
tents of the DM Area, HR Area, and other data required for resuming
operation. Not doing so may result in an unexpected operation.
erate the battery. Do not subject the battery to strong shocks. Doing any
of these may result in leakage, rupture, heat generation, or ignition of the
battery. Dispose of any battery that has been dropped on the floor or oth-
• Changing the operating mode of the PC.
• Force-setting/force-resetting any bit in memory.
• Changing the present value of any word or any set value in memory.
or less must be installed when shorting the GR and LG