CS1W-CN313 Omron, CS1W-CN313 Datasheet - Page 99

no-image

CS1W-CN313

Manufacturer Part Number
CS1W-CN313
Description
"CABLE CS1 EXP I/O,30cm"
Manufacturer
Omron
Datasheet

Specifications of CS1W-CN313

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
CPU Units
3-1-1
Error/Alarm Indicator (Red)
Flashes when there is a
non-fatal error. The CPU Unit
will continue operating.
Lights when there is a fatal
error. The RUN indicator will
go OFF, CPU Unit operation
will stop, and all outputs will
turn OFF.
RUN
ERR/ALM
INH
PRPHL
COMM
Indicators
RUN Indicator (Green)
Lights when the CPU Unit is
operating normally.
RUN
ERR/ALM Red
INH
PRPHL
COMM
Indicator
Green
Yellow
Yellow
Yellow
Color
Output Inhibited Indicator (INH) (Yellow)
Lights when the Output OFF Bit (SR 25212) turns ON.
Outputs from all the Output Units will turn OFF.
Peripheral Port Indicator (PRPHL) (Yellow)
Flashes when the CPU Unit is communicating with another device
via the peripheral port.
Built-in RS-232C Port Indicator (COMM) (Yellow)
Flashes when the CPU Unit is communicating with another device
via the RS-232C port. (Not supported by CQM1H-CPU11.)
0 1 2 3 4 5 6 7
8 9 10 1112 131415
Lit
Not lit
Lit
Flash
Not lit
Lit
Not lit
Lit
Not lit
Lit
Not lit
Status
PC is operating normally in MONITOR or RUN mode.
PC has stopped operating while in PROGRAM mode, or
has stopped operating due to a fatal error.
A fatal error has occurred.
The CPU Unit will stop operating, and the outputs from all
Output Units will turn OFF.
A non-fatal error has occurred.
The CPU Unit will continue operating.
CPU Unit is operating normally or a watchdog timer error
has occurred.
Output OFF Bit (SR 25212) has been turned ON.
The outputs from all Output Units will turn OFF.
Output OFF Bit (SR 25212) is OFF.
CPU Unit is sending or receiving via the peripheral port.
CPU Unit is not communicating via the peripheral port.
CPU Unit is sending or receiving via the built-in RS-232C
port.
CPU Unit is not communicating via the built-in RS-232C
port.
Input Status Indicators
Indicates the ON/OFF status of the input bits in IR 000
corresponding to the CPU Unit's built-in input points.
Meaning
Section 3-1
77

Related parts for CS1W-CN313