CS1W-CN313 Omron, CS1W-CN313 Datasheet - Page 71

no-image

CS1W-CN313

Manufacturer Part Number
CS1W-CN313
Description
"CABLE CS1 EXP I/O,30cm"
Manufacturer
Omron
Datasheet

Specifications of CS1W-CN313

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Unit Specifications
Clock
Input time
constants
Power OFF
detection time
Memory
protection
Sending
commands to a
Host Link com-
puter
Remote
programming and
monitoring
Program check
Battery life
Self-diagnostics
Programming
Console bus
Peripheral bus
Host Link
(SYSMAC WAY)
No-protocol
1:1 Data LInk
NT Link
(1:1 mode,
1:N mode)
Protocol macro
Item
Used for communications with
Programming Consoles.
Used for communications with
Programming Devices such as CX-Pro-
grammer.
Used to access the CPU Unit’s I/O memory
and programs using Host Link commands.
Supports communications with Program-
ming Devices and OMRON PTs. Commu-
nications can be initiated from the CQM1H
in this mode.
Used for sending or receiving up to
256 bytes of data using special instructions
with no protocol or conversion.
Used for 1:1 communications via a data
link with another CQM1H or with a CQM1,
CPM1, C200HX/HG/HE, or C200HS PC.
Used for data exchange with OMRON PTs
without program. One-to-one or
one-to-many (PC:PT) connections sup-
ported.
Note The 1:1 mode and 1:N mode are not
Used to freely exchange data with
general-purpose external devices with a
serial port (e.g., RS-232C).
Note This mode is supported only by a Se-
Some Memory Cassette are equipped with a clock.
Note Used to store the time when errors occur.
Used to set the ON (or OFF) response times for DC Input Units.
Available settings: 1, 2, 4, 8, 16, 32, 64, 128 ms.
AC power supply: 10 to 25 ms, DC power supply: 5 to 25 ms
Held Areas: Holding bits, contents of Data Memory and Extended Data Memory, and status of the
counter Completion Flags and present values.
Note If the I/O Hold Bit (SR 25212) is turned ON, and the PC Setup is set to maintain the
Host Link command responses can be sent to a computer connected via the Host Link System using
the TXD(––) (communications port output) instruction.
Host Link or peripheral bus communications via a CPU Unit’s serial communications port can be used
for remote programming and remote monitoring of the PC through a Controller Link System.
(This function is, however, not supported for the serial communications ports on the Serial
Communications Board.)
Program checks are performed at the beginning of operation for items such as no END(01) instruction
and instruction errors.
CX-Programmer can also be used to check programs. (The level of program checking can be set.)
5 years at 25 C
(Depends on the ambient temperature and power supply conditions. Minimum: 1 year.)
Battery replacement must be performed within 5 minutes.
CPU errors (watchdog timer), I/O verification errors, I/O bus errors, memory errors, FALS system
errors (FALS instruction execution or cycle monitor time over), FAL system errors (FAL instruction
execution or PC Setup error etc.), battery errors, Cycle Time Over errors and communications port
errors.
compatible. Be sure to use the cor-
rect communications port at the PT.
rial Communications Board.
I/O Hold Bit status when power to the PC is turned ON, the contents of the IR area and the LR
area will be saved.
Specification
Yes (SW7: ON)
Yes (SW7: ON)
Yes (SW7: ON)
Yes (SW7: ON)
No
No
No
No
No
Yes
Yes
Yes
Yes (1:1 mode
only)
No
No
No
Yes
Yes
Yes
Yes (1:1 mode or
1:N mode)
Yes
Section 2-1
49

Related parts for CS1W-CN313