PEF22558EV11GXP Lantiq, PEF22558EV11GXP Datasheet - Page 36

PEF22558EV11GXP

Manufacturer Part Number
PEF22558EV11GXP
Description
Manufacturer
Lantiq
Datasheet

Specifications of PEF22558EV11GXP

Screening Level
Industrial
Mounting
Surface Mount
Operating Temperature (min)
-40C
Operating Temperature (max)
85C
Lead Free Status / RoHS Status
Compliant
7
7.1
The basic operation mode (serial or register based) can be selected individually for
receive and transmit direction.
If RSIG is configured on one of the RX multifunction ports RPA...RPC, serial RX-CAS
data on RSIG are used automatically. If XSIG is configured on one of the TX
multifunction ports XPA, RPB, serial TX-CAS data on XSIG are used automatically and
XS1...16 registers are ignored.
7.2
In T1 mode the function to force all robbed bits to “one” can be selected to be not
performed in CAS cleared channels. This mode is selected by setting register bit
XC0.BRFO1 = 1.
7.3
In T1 mode the bit robbing idle function is selectable by register bit XC0.BRIF. If this bit
is set, bit robbing information is not overwritten by the idle code in idle channels.
Delta Sheet
CAS Features
Basic CAS Operation Mode
Bit Robbing Force One in Cleared Channels (T1/J1 only)
Bit Robbing Idle (T1/J1 only)
36
Rev. 2.0, 2005-05-03
OctalFALC
PEF 22558 E
CAS Features
TM

Related parts for PEF22558EV11GXP