HBLXT9785EHC.B2Q E000 Intel, HBLXT9785EHC.B2Q E000 Datasheet - Page 39

no-image

HBLXT9785EHC.B2Q E000

Manufacturer Part Number
HBLXT9785EHC.B2Q E000
Description
Manufacturer
Intel
Datasheet

Specifications of HBLXT9785EHC.B2Q E000

Lead Free Status / RoHS Status
Not Compliant
Datasheet
Document Number: 249241
Revision Number: 010
Revision Date: 30-May-2006
Table 8.
SS-SMII Specific Signal Descriptions – PQFP
1. Type Column Coding: I = Input, O = Output, OD = Open Drain output, ST = Schmitt Triggered input, TS =
2. The IP/ID resistors are disabled during H/W Power-Down mode. If a Pin is an output or an I/O, the IP/ID
3. RxData[0:7], RxSYNC[0:1], and RxCLK[0:1] outputs are three-stated in Isolation and H/W Power-Down
PQFP
204
201
205
197
35
58
17
32
60
21
54
45
36
27
15
Three-State-able output, SL = Slew-rate Limited output, IP = weak Internal Pull-up, ID = weak Internal pull-
Down.
resistors are also disabled when the output is enabled.
modes and during H/W reset.
Designation
7
Pin/Ball
PBGA
C12,
B15,
B17,
LXT9785 and LXT9785E Advanced 8-Port 10/100 Mbps PHY Transceivers
C16
B12
D17
B11
F14
A6,
E4,
C8,
E3,
B1,
B4,
C7,
B9,
TxSYNC0
TxSYNC1
RxSYNC0
RxSYNC1
RxCLK0
RxCLK1
RxData0
RxData1
RxData2
RxData3
RxData4
RxData5
RxData6
RxData7
Symbol
TxCLK0
TxCLK1
O, TS,
O, TS,
O, TS,
Type
I, ID
I, ID
ID
ID
ID
1
Signal Description
SS-SMII Transmit Synchronization.
The MAC must generate a TxSYNC pulse every 10 TxCLK
cycles to mark the start of TxData segments. TxSYNC0 is
used when 1x8 port sectionalization is selected.
SS-SMII Receive Synchronization.
The LXT9785/9785E generates these pulses every 10
RxCLK cycles to mark the start of RxData segments for the
MAC. RxSYNC1 is used when 1x8 port sectionalization is
selected. RxSYNC0 may not be used. These outputs are
only enabled when SS-SMII mode is enabled.
SS-SMII Transmit Clock.
The MAC sources this 125 MHz clock as the timing
reference for TxData and TxSYNC. Only TxCLK0 is used
when 1x8 port sectionalization is selected.
SYNC Requirements” on page 124
requirements.
SS-SMII Receive Clock.
The LXT9785/9785E generates these clocks, based on
REFCLK, to provide a timing reference for RxData and
RxSYNC to the MAC. RxCLK1 is used when 1x8 port
sectionalization is selected. RxCLK0 may not be used.
“Clock/SYNC Requirements” on page 124
requirements.
SMII mode is enabled.
Receive Data - Ports 0-7.
These serial output streams provide data received from
the network. The LXT9785/9785E drives the data out
synchronously to REFCLK.
These outputs are only enabled when SS-
2,3
for detailed clock
for detailed clock
See “Clock/
See
39