PEF2054NV21XK Infineon Technologies, PEF2054NV21XK Datasheet - Page 185

no-image

PEF2054NV21XK

Manufacturer Part Number
PEF2054NV21XK
Description
Manufacturer
Infineon Technologies
Datasheet

Specifications of PEF2054NV21XK

Lead Free Status / Rohs Status
Compliant
Table 31
CM Address
Even time slot downstream
Odd time slot downstream
Even time slot upstream
Odd time slot upstream
Example
In CFI mode 3, downstream time slots 2 and 3 and upstream time slots 6 and 7 of port
0 shall be initialized for 8 bit signaling channel handling:
W:MADR
W:MAAR
W:MACR
W:MADR
W:MAAR
W:MACR
W:MADR
W:MAAR
W:MACR
W:MADR
W:MAAR
W:MACR
8-Bit Signaling Scheme
This option is intended for SLD channels where the even time slot consists of an 8 bit
feature control channel and the odd time slot of an 8 bit signaling channel.
The feature control channel is handled by the MF handler according to the selected
protocol, handshake or non-handshake. Note that only the non-handshake mode makes
sense in SLD applications.
The 8 bit SIG channel can be accessed by the P for controlling codec filter devices. In
upstream direction each valid change in the SIG value is reported by interrupt to the P
and the CFI time slot address is stored in the CIFIFO (refer to chapter 5.5.2). The
change detection mechanism consists of a double last look logic with a programmable
period.
To initialize two consecutive CFI time slots for the 8 bit signaling channel scheme, the
CM codes as given in table 31 must be used:
Semiconductor Group
= 0100 0101
= 0001 0000
= 0111 1011
= XXXX XXXX
= 0001 0001
= 0111 1011
= 1101 0110
= 1011 0000
= 0111 1011
= 1101 0110
= 1011 0001
= 0111 1011
B
B
B
B
B
B
B
B
B
B
B
B
CM Code
1010
1011
1011
1011
; SIG value “0100 0101”
; downstream even TS, port 0 time slot 2
; write CM code + data fields, CM code “1011”
; don’t care
; downstream odd TS, port 0 time slot 3
; write CM code + data fields, CM code “1011”
; expected SIG value “1101 0110”
; upstream even TS, port 0 time slot 6
; write CM code + data fields, CM code “1011”
; expected SIG value “1101 0110”
; upstream odd TS, port 0 time slot 7
; write CM code + data fields, CM code “1011”
185
CM Data
SIG
XXXXXXXX
actual value
stable value
B
Application Hints
B
B
B
PEB 2055
PEF 2055