HD64570F16 Renesas Electronics America, HD64570F16 Datasheet - Page 142

no-image

HD64570F16

Manufacturer Part Number
HD64570F16
Description
IC SCA SRL COMM ADAPTER 88QFP
Manufacturer
Renesas Electronics America
Datasheet

Specifications of HD64570F16

Applications
ISDN
Interface
Serial
Voltage - Supply
4.75 V ~ 5.25 V
Package / Case
88-QFP
Mounting Type
Surface Mount
Operating Supply Voltage (typ)
5V
Operating Supply Voltage (min)
4.5V
Operating Supply Voltage (max)
5.5V
Operating Temp Range
-20C to 75C
Operating Temperature Classification
Commercial
Mounting
Surface Mount
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HD64570F16
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Part Number:
HD64570F16
Manufacturer:
HIT
Quantity:
1 000
Part Number:
HD64570F16
Manufacturer:
HITACHI/日立
Quantity:
20 000
Part Number:
HD64570F16V
Manufacturer:
INFINEON
Quantity:
12 000
Specific values are listed in table 5.21, Register Values and Bit Rates in Asynchronous Mode, and
table 5.22, Register Values and Bit Rates in Byte Synchronous/Bit Synchronous Mode.
5.2.8
The command register (CMD) specifies the command for MSCI transmission/reception control.
This is a write-only register and always reads 00H.
Bits 7–6: Reserved. These bits always read 0 and must be set to 0.
Bits 5–0 (CMD5–CMD0: Command): The functions of these bits are described below.
Rev. 0, 07/98, page 126 of 453
Asynchronous/Byte synchronous/Bit synchronous mode
Bits 5–0 specify three types of commands: transmit, receive, and other commands. These
commands and their values are described in table 5.1 to table 5.3.
Async
Byte sync
Bit sync HDLC
Read/Write
Initial value
• Transmit commands
000001:
000010:
000011:
000100:
000101:
000110:
000111:
001000:
001001:
Others:
Notes:
MSCI Command Register (CMD)
1. Reserved. These bits always read 0 and must be set to 0.
2. When this setting is selected, normal operation is not guaranteed.
TX reset
TX enable
TX disable
TX CRC initialization
TX CRC calculation
exclusion
End-of-message
Abort transmission
MP bit on
TX buffer clear
Reserved
7
*1
*2
6
*1
CMD5
W
• Receive commands
010001:
010010:
010011:
010100:
010101:
010110:
010111:
011000:
5
CMD4
W
4
RX reset
RX enable
RX disable
RX CRC initialization
Message reject
Search MP bit
RX CRC calculation
exclusion
Forcing RX CRC
calculation
CMD3
W
Command
3
CMD2
W
2
CMD1
W
• Other commands
100001:
110001:
000000:
1
CMD0
W
0
Channel reset
Enter search mode
No operation

Related parts for HD64570F16