ATxmega32A4U Atmel Corporation, ATxmega32A4U Datasheet - Page 418

no-image

ATxmega32A4U

Manufacturer Part Number
ATxmega32A4U
Description
Manufacturer
Atmel Corporation
Datasheets

Specifications of ATxmega32A4U

Flash (kbytes)
32 Kbytes
Pin Count
44
Max. Operating Frequency
32 MHz
Cpu
8-bit AVR
# Of Touch Channels
16
Hardware Qtouch Acquisition
No
Max I/o Pins
34
Ext Interrupts
34
Usb Transceiver
1
Usb Speed
Full Speed
Usb Interface
Device
Spi
7
Twi (i2c)
2
Uart
5
Graphic Lcd
No
Video Decoder
No
Camera Interface
No
Adc Channels
12
Adc Resolution (bits)
12
Adc Speed (ksps)
2000
Analog Comparators
2
Resistive Touch Screen
No
Dac Channels
2
Dac Resolution (bits)
12
Temp. Sensor
Yes
Crypto Engine
AES/DES
Sram (kbytes)
4
Eeprom (bytes)
1024
Self Program Memory
YES
Dram Memory
No
Nand Interface
No
Picopower
Yes
Temp. Range (deg C)
-40 to 85
I/o Supply Class
1.6 to 3.6
Operating Voltage (vcc)
1.6 to 3.6
Fpu
No
Mpu / Mmu
no / no
Timers
5
Output Compare Channels
16
Input Capture Channels
16
Pwm Channels
16
32khz Rtc
Yes
Calibrated Rc Oscillator
Yes

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ATxmega32A4U-AU
Manufacturer:
ON
Quantity:
1 140
Part Number:
ATxmega32A4U-AU
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
ATxmega32A4U-AUR
Manufacturer:
ATMEL/爱特梅尔
Quantity:
20 000
Part Number:
ATxmega32A4U-CU
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
ATxmega32A4U-CU
Manufacturer:
ATMEL/爱特梅尔
Quantity:
20 000
32.4.7
32.5
8331A–AVR–07/11
PDI Controller
Serial Reception
If the PDI is in TX- mode (as a response to an LD instruction), but no transmission request from
the PDI controller is pending when the TAP controller enters the capture DR state, a DELAY
byte (0xDB) will be loaded into the shift register, and the parity bit will be set (forcing a parity
error) when data is shifted out in the shift DR state. This situation occurs during data transmis-
sion if the data to be transmitted is not yet available.
Figure 32-13 on page 418
response to the repeated indirect LD instruction. In this example, the device is not able to return
data bytes faster than one valid byte per two transmitted frames. Thus, intermediate DELAY
characters are inserted.
Figure 32-13. Data not ready marking.
If a DELAY data frame is transmitted as a response to an LD instruction, the programmer should
interpret this as if the JTAG interface had no data ready for transmission in the previous capture
DR state. The programmer must initiate repeated transfers until a valid data byte is received.
The LD instruction is defined to return a specified number of valid frames, not just a number of
frames. Hence, if the programmer detects a DELAY character after transmitting an LD instruc-
tion, the LD instruction should not be retransmitted, because the first LD response would still be
pending.
During reception, the PDI collects the eight data bits and the parity bit from TDI and shifts them
into the shift register. Every time a valid frame is received, the data is latched in to the update
DR state.
The parity checker calculates the parity (even mode) of the data bits in incoming frames and
compares the result with the parity bit from the serial frame. In case of a parity error, the PDI
controller is signaled.
The parity checker is active in both TX and RXmodes. If a parity error is detected, the received
data byte is evaluated and compared with the BREAK character (which will always generate a
parity error). In case the BREAK character is recognized, the PDI controller is signaled.
The PDI controller performs data transmission/reception on a byte level, command decoding,
high-level direction control, control and status register access, exception handling, and clock
switching (PDI_CLK or TCK). The interaction between an external programmer and the PDI con-
troller is based on a scheme where the programmer transmits various types of requests to the
PDI controller, which in turn responds according to the specific request. A programmer request
comes in the form of an instruction, which may be followed by one or more byte operands. The
PDI controller response may be silent (e.g., a data byte is stored to a location within the device),
or it may involve data being returned to the programmer (e.g., a data byte is read from a location
within the device).
Programmer
External
Commands/data
Device
FRAME 0
REP
shows an uninterrupted flow of data frames from the PDI as a
FRAME 1
CNT
LD *(ptr)
FRAME 2
Atmel AVR XMEGA AU
0xDB 1
FRAME 0
FRAME 1
D0
P 0xDB 1
FRAME 2
FRAME 3
D1
P
418