ST7LITE49M STMicroelectronics, ST7LITE49M Datasheet - Page 120

no-image

ST7LITE49M

Manufacturer Part Number
ST7LITE49M
Description
8-bit MCU
Manufacturer
STMicroelectronics
Datasheet

Specifications of ST7LITE49M

4 Kbytes Single Voltage Extended Flash (xflash) Program Memory With Read-out Protection In-circuit Programming And In-application Programming (icp And Iap) Endurance
10k write/erase cycles guaranteed Data retention
128 Bytes Data Eeprom With Read-out Protection. 300k Write/erase Cycles Guaranteed, Data Retention
20 years at 55 °C.
Clock Sources
Internal trimmable 8 MHz RC oscillator, auto-wakeup internal low power - low frequency oscillator, crystal/ceramic resonator or external clock
Five Power Saving Modes
Halt, Active-halt, Auto-wakeup from Halt, Wait and Slow
A/d Converter
10 input channels

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ST7LITE49M
Manufacturer:
ST
0
On-chip peripherals
120/188
Bit 3 = BTF Byte transfer finished bit
Bit 2 = ADSL Address matched bit (slave mode).
Bit 1 = M/SL Master/Slave bit
Bit 0 = SB Start bit (master mode).
This bit is set by hardware as soon as a byte is correctly received or transmitted with
interrupt generation if ITE=1. It is cleared by software reading SR1 register followed by
a read or write of DR register. It is also cleared by hardware when the interface is
disabled (PE=0).
The SCL line is held low while BTF=1.
0: byte transfer not done
1: byte transfer succeeded
This bit is set by hardware as soon as the received slave address matched with the
OAR register content or a general call is recognized. An interrupt is generated if ITE=1.
It is cleared by software reading SR1 register or by hardware when the interface is
disabled (PE=0).
The SCL line is held low while ADSL=1.
0: Address mismatched or not received
1: Received address matched
This bit is set by hardware as soon as the interface is in Master mode (writing
START=1). It is cleared by hardware after detecting a Stop condition on the bus or a
loss of arbitration (ARLO=1). It is also cleared when the interface is disabled (PE=0).
0: Slave mode
1: Master mode
This bit is set by hardware as soon as the Start condition is generated (following a write
START=1). An interrupt is generated if ITE=1. It is cleared by software reading SR1
register followed by writing the address byte in DR register. It is also cleared by
hardware when the interface is disabled (PE=0).
0: No Start condition
1: Start condition generated
Following a byte transmission, this bit is set after reception of the acknowledge
clock pulse. In case an address byte is sent, this bit is set only after the EV6 event
(See
next byte in DR register.
Following a byte reception, this bit is set after transmission of the acknowledge
clock pulse if ACK=1. BTF is cleared by reading SR1 register followed by reading
the byte from DR register.
Figure
57). BTF is cleared by reading SR1 register followed by writing the
Doc ID 13562 Rev 3
ST7LITE49M

Related parts for ST7LITE49M