mfrc531 NXP Semiconductors, mfrc531 Datasheet - Page 86

no-image

mfrc531

Manufacturer Part Number
mfrc531
Description
Iso/iec 14443 Reader Ic
Manufacturer
NXP Semiconductors
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MFRC531
Quantity:
5
Part Number:
MFRC531
Manufacturer:
NXP/恩智浦
Quantity:
20 000
Part Number:
mfrc531-01T
Manufacturer:
MFRC
Quantity:
20 000
Company:
Part Number:
mfrc531-01T
Quantity:
420
Part Number:
mfrc53101T
Manufacturer:
TI
Quantity:
11 793
Part Number:
mfrc53101T
Manufacturer:
NXP/恩智浦
Quantity:
20 000
Company:
Part Number:
mfrc53101T
Quantity:
37
Company:
Part Number:
mfrc53101T
Quantity:
37
Part Number:
mfrc53101T/0FE
Manufacturer:
NXP
Quantity:
3 000
Part Number:
mfrc53101T/0FE
Manufacturer:
ST
Quantity:
3
Part Number:
mfrc53101T/0FE
Manufacturer:
NXP/恩智浦
Quantity:
20 000
Part Number:
mfrc53101T/0FE,112
Manufacturer:
NXP/恩智浦
Quantity:
20 000
Part Number:
mfrc53101T/0FE.112
0
Part Number:
mfrc53101T/OFE
Manufacturer:
NXP
Quantity:
5 000
NXP Semiconductors
MFRC531_34
Product data sheet
PUBLIC
11.3.2.1 ReadE2 command error flags
11.4.1.1 Register assignment
11.3.2 ReadE2 command 03h
11.4.1 LoadConfig command 07h
11.4 Diverse commands
Table 140. ReadE2 command 03h
The ReadE2 command interprets the first two bytes stored in the FIFO buffer as the
EEPROM starting byte address. The next byte specifies the number of data bytes
returned.
When all three argument bytes are available in the FIFO buffer, the specified number of
data bytes are copied from the EEPROM into the FIFO buffer, starting from the given
EEPROM starting byte address.
The ReadE2 command can only be triggered by the microprocessor and it automatically
stops when all data has been copied.
Reading is restricted to EEPROM blocks 8h to 1Fh (key memory area). Reading from
these addresses sets the flag AccessErr = logic 1.
Addresses above 1FFh are taken as modulo 200h; see
EEPROM memory organization.
Table 141. LoadConfig command 07h
The LoadConfig command interprets the first two bytes found in the FIFO buffer as the
EEPROM starting byte address. When the two argument bytes are available in the FIFO
buffer, 32 bytes from the EEPROM are copied into the Control and other relevant
registers, starting at the EEPROM starting byte address. The LoadConfig command can
only be started by the microprocessor and it automatically stops when all relevant
registers have been copied.
The 32 bytes of EEPROM content are written to the MFRC531 registers 10h to register
2Fh; see
Remark: The procedure for the register assignment is the same as it is for the startup
initialization (see
address for the StartUp initialization is fixed to 10h (block 1, byte 0). However, it can be
chosen with the LoadConfig command.
Command
ReadE2
Command
LoadConfig
Section 9.2 on page 12
Value Action
03h
Value Action
07h
Section 9.7.3 on page
reads EEPROM data and
stores it in the FIFO buffer
Rev. 3.4 — 26 January 2010
reads data from EEPROM and
initializes the registers
056634
for the EEPROM memory organization.
28). The difference is, the EEPROM starting byte
Arguments
start address LSB
start address MSB
number of data bytes
Arguments and
data
start address LSB
start address MSB
Section 9.2 on page 12
ISO/IEC 14443 reader IC
MFRC531
© NXP B.V. 2010. All rights reserved.
Returned data
data bytes
Returned data
-
-
for the
86 of 116

Related parts for mfrc531