MCIMX6D7CVT08AC Freescale Semiconductor, MCIMX6D7CVT08AC Datasheet - Page 100

no-image

MCIMX6D7CVT08AC

Manufacturer Part Number
MCIMX6D7CVT08AC
Description
Processors - Application Specialized i.MX6D
Manufacturer
Freescale Semiconductor
Type
Multimedia Applicationsr
Datasheet

Specifications of MCIMX6D7CVT08AC

Rohs
yes
Core
ARM Cortex A9
Processor Series
i.MX6
Data Bus Width
32 bit
Maximum Clock Frequency
800 MHz
Data Ram Size
16 KB
Maximum Operating Temperature
+ 105
Mounting Style
SMD/SMT
Package / Case
FCBGA
Interface Type
I2C, I2S, UART, USB
Memory Type
L1/L2 Cache, ROM, SRAM
Minimum Operating Temperature
- 40 C
Number Of Timers
2

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MCIMX6D7CVT08AC
Manufacturer:
Freescale Semiconductor
Quantity:
10 000
Part Number:
MCIMX6D7CVT08AC
0
Electrical Characteristics
The IPU has a system of internal binding counters for internal events (such as, HSYNC/VSYNC)
calculation. The internal event (local start point) is synchronized with internal DI_CLK. A suitable control
starts from the local start point with predefined UP and DOWN values to calculate control’s changing
points with half DI_CLK resolution. A full description of the counter system can be found in the IPU
chapter of the i.MX 6Dual/6Quad reference manual (IMX6DQRM).
4.11.10.5.2 Asynchronous Controls
The asynchronous control is a data-oriented signal that changes its value with an output data according to
additional internal flags coming with the data.
There are special physical outputs to provide asynchronous controls, as follows:
4.11.10.6 Synchronous Interfaces to Standard Active Matrix TFT LCD Panels
4.11.10.6.1 IPU Display Operating Signals
The IPU uses four control signals and data to operate a standard synchronous interface:
All synchronous display controls are generated on the base of an internally generated “local start point”.
The synchronous display controls can be placed on time axis with DI’s offset, up and down parameters.
The display access can be whole number of DI clock (Tdiclk) only. The IPP_DATA can not be moved
relative to the local start point. The data bus of the synchronous interface is output direction only.
4.11.10.6.2 LCD Interface Functional Description
Figure 66
signals are shown with negative polarity. The sequence of events for active matrix interface timing is:
100
The ipp_pin_1– ipp_pin_7 are general purpose synchronous pins, that can be used to provide
HSYNC, VSYNC, DRDY or any else independent signal to a display.
The ipp_d0_cs and ipp_d1_cs pins are dedicated to provide chip select signals to two displays.
The ipp_pin_11– ipp_pin_17 are general purpose asynchronous pins, that can be used to provide
WR. RD, RS or any other data-oriented signal to display.
IPP_DISP_CLK—Clock to display
HSYNC—Horizontal synchronization
VSYNC—Vertical synchronization
DRDY—Active data
DI_CLK internal DI clock is used for calculation of other controls.
depicts the LCD interface timing for a generic active matrix color TFT panel. In this figure,
The IPU has independent signal generators for asynchronous signals
toggling. When a DI decides to put a new asynchronous data on the bus, a
new internal start (local start point) is generated. The signal generators
calculate predefined UP and DOWN values to change pins states with half
DI_CLK resolution.
i.MX 6Dual/6Quad Applications Processors for Industrial Products, Rev. 2
NOTE
Freescale Semiconductor

Related parts for MCIMX6D7CVT08AC