UPD70F3738GF-GAS-AX Renesas Electronics America, UPD70F3738GF-GAS-AX Datasheet - Page 460

no-image

UPD70F3738GF-GAS-AX

Manufacturer Part Number
UPD70F3738GF-GAS-AX
Description
MCU 32BIT V850ES/JX3-L 100-LQFP
Manufacturer
Renesas Electronics America
Series
V850ES/Jx3-Lr
Datasheet

Specifications of UPD70F3738GF-GAS-AX

Core Processor
RISC
Core Size
32-Bit
Speed
20MHz
Connectivity
CSI, EBI/EMI, I²C, UART/USART
Peripherals
DMA, LVD, PWM, WDT
Number Of I /o
84
Program Memory Size
256KB (256K x 8)
Program Memory Type
FLASH
Ram Size
16K x 8
Voltage - Supply (vcc/vdd)
2.2 V ~ 3.6 V
Data Converters
A/D 12x10b; D/A 2x8b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
*
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
UPD70F3738GF-GAS-AX
Manufacturer:
Renesas Electronics America
Quantity:
10 000
<R>
11.1 Functions
458
The real-time counter (RTC) has the following features.
• Counting up to 99 years using year, month, day-of-week, day, hour, minute, and second sub-counters provided
• Year, month, day-of-week, day, hour, minute, and second counter display using BCD codes
• Alarm interrupt function
• Constant-period interrupt function (period: 1 month to 0.5 second)
• Interval interrupt function (period: 1.95 ms to 125 ms)
• Pin output function of 1 Hz
• Pin output function of 32.768 kHz
• Pin output function of 512 Hz or 16.384 kHz
• Watch error correction function
• Subclock operation or main clock operation
Notes 1. A BCD (binary coded decimal) code expresses each digit of a decimal number in 4-bit binary format.
Cautions1.
Year, month, day-of-week,
day, hour, minute,
sub-coubters count function
Interrupt function (alarm,
constant-period, interval)
Pin output function
(32.768 kHz, 16.384 kHz,
512 kHz, 1Hz)
Watch error correction
function
2. Use the baud rate generator dedicated to the real-time counter to divide the main clock frequency to
2. If the normal operating mode is restored after entering the RTC backup mode, an error of up
3. The usable RTC functions differ as shown below in the normal operating mode and RTC
32.768 kHz for use.
The watch timer and RTC alternate interrupt signal and therefore cannot be used
simultaneously.
to 1 second might occur for the RTC subcounter.
backup mode.
Function
CHAPTER 11 REAL-TIME COUNTER (
enable
enable
enable
enable
User’s Manual U18953EJ5V0UD
Normal operation mode
Note 2
selectable
μ
PD70F3792, 70F3793)
enable
disable
disable
disable
RTC backup mode
Note 1