ISP1181BDGG ST-Ericsson Inc, ISP1181BDGG Datasheet - Page 38

no-image

ISP1181BDGG

Manufacturer Part Number
ISP1181BDGG
Description
IC USB CNTRLR FULL-SPD 48-TSSOP
Manufacturer
ST-Ericsson Inc
Datasheet

Specifications of ISP1181BDGG

Controller Type
USB Peripheral Controller
Interface
Parallel
Voltage - Supply
3.3V, 5V
Current - Supply
26mA
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Package / Case
48-TSSOP
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
568-1002-5
ISP1181BDGG,112

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ISP1181BDGG
Manufacturer:
NXP
Quantity:
1 200
Part Number:
ISP1181BDGG
Manufacturer:
NXPLIPS
Quantity:
5 510
Part Number:
ISP1181BDGG
Manufacturer:
NXP/恩智浦
Quantity:
20 000
Philips Semiconductors
Table 38:
9397 750 13958
Product data
Bit
Symbol
Reset
Access
Lock Register: bit allocation
15
W
1
12.3.2 Unlock Device
Table 36:
Table 37:
This command unlocks the ISP1181B from write-protection mode after a ‘resume’. In
‘suspend’ state all registers and FIFOs are write-protected to prevent data corruption
by external devices during a ‘resume’. Also, the register access for reading is possible
only after the ‘Unlock Device’ command is executed.
After waking up from ‘suspend’ state, the firmware must unlock the registers and
FIFOs via this command, by writing the unlock code (AA37H) into the Lock Register
(8-bit bus: lower byte first). The bit allocation of the Lock Register is given in
Code (Hex): B0 — unlock the device
Transaction — write 2 bytes (unlock code)
Bit
5
4 to 1
0
Error code
(Binary)
0000
0001
0010
0011
0100
0101
0110
0111
1000
1001
1010
1011
1100
1101
1110
1111
14
W
0
Transaction error codes
Error Code Register: bit description
Symbol
-
ERROR[3:0]
RTOK
Description
no error
PID encoding error; bits 7 to 4 are not the inverse of bits 3 to 0
PID unknown; encoding is valid, but PID does not exist
unexpected packet; packet is not of the expected type (token, data, or
acknowledge), or is a SETUP token to a non-control endpoint
token CRC error
data CRC error
time-out error
babble error
unexpected end-of-packet
sent or received NAK (Not AcKnowledge)
sent Stall; a token was received, but the endpoint was stalled
overflow; the received packet was larger than the available buffer space
sent empty packet (ISO only)
bit stuffing error
sync error
wrong (unexpected) toggle bit in DATA PID; data was ignored
13
W
1
Rev. 02 — 07 December 2004
UNLOCKH[7:0] = AAH
Description
reserved
Error code. For error description, see
A logic 1 indicates that data was received or transmitted
successfully.
12
W
0
11
W
1
Full-speed USB peripheral controller
…continued
10
W
0
© Koninklijke Philips Electronics N.V. 2004. All rights reserved.
Table
ISP1181B
W
9
1
37.
Table
W
8
0
37 of 70
38.

Related parts for ISP1181BDGG