mc68hc908jb16 Freescale Semiconductor, Inc, mc68hc908jb16 Datasheet - Page 159

no-image

mc68hc908jb16

Manufacturer Part Number
mc68hc908jb16
Description
M68hc08 Microcontrollers Microcontroller
Manufacturer
Freescale Semiconductor, Inc
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
mc68hc908jb16DW
Manufacturer:
FREESCALE
Quantity:
20 000
Part Number:
mc68hc908jb16DWE
Manufacturer:
MOTOROLA/摩托罗拉
Quantity:
20 000
Part Number:
mc68hc908jb16FA
Manufacturer:
FREESCALE
Quantity:
1 831
Part Number:
mc68hc908jb16FA
Manufacturer:
Freescale Semiconductor
Quantity:
10 000
Part Number:
mc68hc908jb16FAE
Manufacturer:
FREESCALE
Quantity:
331
Part Number:
mc68hc908jb16JDWE
Manufacturer:
FREESCALE
Quantity:
1 250
Part Number:
mc68hc908jb16JDWE
Manufacturer:
FREESCALE
Quantity:
1 250
Part Number:
mc68hc908jb16JDWE
Manufacturer:
FREESCALE
Quantity:
20 000
Company:
Part Number:
mc68hc908jb16JDWE
Quantity:
1 487
10.10.5 TIM Channel Registers
MC68HC908JB16
Freescale Semiconductor
NOTE:
NOTE:
Rev. 1.1
Before enabling a TIM channel register for input capture operation, make
sure that the TCHx pin is stable for at least two bus clocks.
TOVx — Toggle On Overflow Bit
When TOVx is set, a TIM counter overflow takes precedence over a
channel x output compare if both occur at the same time.
CHxMAX — Channel x Maximum Duty Cycle Bit
These read/write registers contain the captured TIM counter value of the
input capture function or the output compare value of the output
compare function. The state of the TIM channel registers after reset is
unknown.
CHxMAX
TCHx
When channel x is an output compare channel, this read/write bit
controls the behavior of the channel x output when the TIM counter
overflows. When channel x is an input capture channel, TOVx has no
effect.
Reset clears the TOVx bit.
When the TOVx bit is at logic 1, setting the CHxMAX bit forces the
duty cycle of buffered and unbuffered PWM signals to 100%. As
Figure 10-11
is set or cleared. The output stays at the 100% duty cycle level until
the cycle after CHxMAX is cleared.
1 = Channel x pin toggles on TIM counter overflow
0 = Channel x pin does not toggle on TIM counter overflow
OVERFLOW
Timer Interface Module (TIM)
COMPARE
PERIOD
OUTPUT
shows, the CHxMAX bit takes effect in the cycle after it
Figure 10-11. CHxMAX Latency
OVERFLOW
COMPARE
OUTPUT
OVERFLOW
COMPARE
OUTPUT
OVERFLOW
Timer Interface Module (TIM)
COMPARE
OUTPUT
OVERFLOW
Technical Data