zl30119 Zarlink Semiconductor, zl30119 Datasheet - Page 15

no-image

zl30119

Manufacturer Part Number
zl30119
Description
Low Jitter Line Card Synchronizer
Manufacturer
Zarlink Semiconductor
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
zl30119GGG2
Manufacturer:
MAXIM
Quantity:
5
Part Number:
zl30119GGG2
Manufacturer:
ZARLINK
Quantity:
20 000
Coarse Frequency Monitor (CFM)
The CFM block monitors the reference frequency over a measurement period of 30 2s so that it can quickly detect
large changes in frequency. A CFM failure (cfm_fail) is triggered when the frequency has changed by more than 3%
or approximately 30000 ppm.
Precise Frequency Monitor (PFM)
The PFM block measures the frequency accuracy of the reference over a 10 second interval. To ensure an
accurate frequency measurement, the PFM measurement interval is re-initiated if phase or frequency irregularities
are detected by the SCM or CFM. The PFM provides a level of hysteresis between the acceptance range and the
rejection range to prevent a failure indication from toggling between valid and invalid for references that are on the
edge of the acceptance range.
When determining the frequency accuracy of the reference input, the PFM uses the external oscillator’s output
frequency (f
Guard Soak Timer (GST)
The GST block mimics the operation of an analog integrator by accumulating failure events from the CFM and the
SCM blocks and applying a selectable rate of decay when no failures are detected.
As shown in Figure 5, a GST failure (gst_fail) is triggered when the accumulated failures have reached the upper
threshold during the disqualification observation window. When there are no CFM or SCM failures, the accumulator
decrements until it reaches its lower threshold during the qualification window.
All sync inputs (sync0 to sync2) are continuously monitored to ensure that there is a correct number of reference
clock cycles within the frame pulse period.
1.5
The ZL30119 offers a wide variety of outputs including two low-jitter differential LVPECL clocks (diff0_p/n,
diff1_p/n), two SONET/SDH LVCMOS (sdh_clk0, sdh_clk1) output clocks and four programmable LVCMOS
(p0_clk0, p0_clk1, p1_clk0, p1_clk1) output clocks. In addition to the clock outputs, two LVCMOS SONET/SDH
frame pulse outputs (sdh_fp0, sdh_fp1) and two LVCMOS programmable frame pulses (p0_fp0, p0_fp1) are also
available.
upper threshold
lower threshold
gst_fail
Output Clocks and Frame Pulses
ref
ocsi
) as its point of reference.
Figure 5 - Behaviour of the Guard Soak Timer during CFM or SCM Failures
t
d
t
q
Zarlink Semiconductor Inc.
CFM or SCM failures
ZL30119
t
t
d
q
- disqualification time
- qualification time = n * t
15
d
Data Sheet

Related parts for zl30119