PEF2091 Siemens Semiconductor Group, PEF2091 Datasheet - Page 189

no-image

PEF2091

Manufacturer Part Number
PEF2091
Description
ICs for Communications(ISDN Echocancellation Circuit)
Manufacturer
Siemens Semiconductor Group
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
PEF2091
Manufacturer:
Infineon
Quantity:
15
Part Number:
PEF2091
Manufacturer:
SIEMENS
Quantity:
5 510
Part Number:
PEF2091
Manufacturer:
SMC
Quantity:
5 510
Part Number:
PEF2091-N
Manufacturer:
INFINEON
Quantity:
2 100
Part Number:
PEF2091-NV3.3
Manufacturer:
DIODES
Quantity:
1 700
Part Number:
PEF2091N-V3.3
Manufacturer:
SIEMENS/西门子
Quantity:
20 000
Part Number:
PEF2091NV3.3
Manufacturer:
ST
0
4.7.2.1
When receiving the EOC-command LBBD in Auto mode, the NT IEC-Q does not close
the loop-back immediately. Because the intention of this loop-back is to test the complete
NT, the IEC-Q passes the complete loop-back request on to the next downstream
device. This is achieved by issuing the C/I-code AIL in the "Transparent" state or C/I =
ARL in states different than "Transparent" (see "State Machine in NT Modes", page 160).
If the downstream device is not able to close the complete loop-back, a MON-8-message
LBBD may be returned to the NT IEC-Q. This then will close the complete loop-back
within the IEC-Q itself (B1 + B2 + D-channels). All remaining IOM
(monitor, C/I-channel as well as the bits MR and MX) are still read from the IOM
the µP interface (if used). For this reason it is still possible for a layer-2 device to
deactivate the NT despite the fact that the loop-backs are controlled by the exchange.
Note 53: If operated in EOC Auto mode, the complete loop-back can only be
In EOC Auto mode the complete loop-back is reset after RTN has been received in the
EOC-channel. In the EOC Transparent mode MON-8 NORM is used for this purpose. No
reset as for loop-backs #1 or #3 is required for loop-back #2. The line is active and ready
for data transmission.
As an example Figure 81 illustrates these two options if the IEC-Q is used together with
the SBC-X and the ICC.
Figure 81
Semiconductor Group
closed in the IEC-Q if previously the EOC-command LBBD was
received. Without this EOC-message the MON-8-command LBBD will be
ignored.
If operated in EOC Transparent mode, a complete loop-back may be
closed at any time with MON-8 LBBD.
Complete Loop-Back
Complete Loop-Back Options in NT modes
2 B + D
SBCX
C/I = AIL/ARL
ICC
MON-8 "LBBD"
189
ITD04219
2 B + D
Auto-Mode
IEC-Q
EOC "LBBD"
Operational Description
=
U
Data Sheet 01.99
®
-2-information
PEB 2091
PEF 2091
®