CDB5467U Cirrus Logic Inc, CDB5467U Datasheet - Page 39

BOARD EVAL FOR CS5467 ADC

CDB5467U

Manufacturer Part Number
CDB5467U
Description
BOARD EVAL FOR CS5467 ADC
Manufacturer
Cirrus Logic Inc
Type
A/Dr
Datasheets

Specifications of CDB5467U

Main Purpose
Power Management, Energy/Power Meter
Embedded
Yes, MCU, 8-Bit
Utilized Ic / Part
CS5467
Primary Attributes
Watt-Hour Meter
Secondary Attributes
Graphical User Interface, SPI™ & USB Interfaces
Product
Data Conversion Development Tools
Maximum Clock Frequency
4 MHz
Interface Type
USB
Supply Voltage (max)
5 V
Supply Voltage (min)
3.3 V
For Use With/related Products
CS5467
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Contains lead / RoHS non-compliant
Other names
598-1555
CDB-5467U
8.4 Page 2 Registers
8.4.1 Voltage Sag and Current Fault Duration (V1Sag
8.4.2 Voltage Sag and Current Fault Level (V1Sag
8.5 Page 5 Register
8.5.1 Temperature Measurement (T
DS714F1
MSB
MSB
MSB
-(2
2
0
23
0
)
Address: 0 ( V1Sag
Default = 0
Voltage sag duration, V1Sag
the count of output word rate (OWR) samples utilized to determine a sag or fault event. These are integers in
the range of 0 to 8,388,607 samples. A value of zero disables the feature.
Address: 1 ( V1Sag
Default = 0
Voltage sag level, V1Sag
an input level below which a sag or fault is triggered. These are two's complement values in the range of
-1.0 ≤ value < 1.0, with the binary point to the right of the MSB. Negative values are not used.
Default = 0
The Temperature Measurement ( T
measurement. Writing a one to the LSB causes the temperature to be measured and the Temperature register
( T ) to be updated.
Refer to
2
2
2
22
22
-1
6.13 Temperature Measurement
2
2
2
21
21
-2
2
2
2
20
20
-3
DUR
LEVEL
), 8 ( V2Sag
2
2
2
), 9 ( V2Sag
LEVEL
19
19
-4
DUR
2
( V2Sag
2
2
18
18
-5
( V2Sag
MEAS
MEAS
DUR
LEVEL
2
2
2
LEVEL
), 4 ( I1Fault
17
17
-6
)
) register is used to cycle-steal voltage channel2 for temperature
DUR
on page 22 for more information.
), 5 ( I1Fault
Address: 26
) and current fault duration, I1Fault
) and current fault level, I1Fault
2
2
2
16
16
-7
LEVEL
DUR
.....
.....
.....
DUR
LEVEL
), 12 ( I2Fault
, V2Sag
, V2Sag
2
2
2
), 13 ( I2Fault
-17
6
6
LEVEL
2
DUR
2
2
-18
DUR
5
5
, I1Fault
, I1Fault
)
LEVEL
2
2
2
-19
4
4
LEVEL
)
DUR
DUR
2
LEVEL
2
2
-20
( I2Fault
3
3
( I2Fault
, I2Fault
, I2Fault
2
2
2
-21
2
2
LEVEL
DUR
CS5467
DUR
2
) determine
2
2
) establish
-22
LEVEL
1
1
)
LSB
LSB
LSB
2
2
2
-23
)
0
0
39

Related parts for CDB5467U