SI1005-C-GM Silicon Laboratories Inc, SI1005-C-GM Datasheet - Page 352

IC TXRX MCU + EZRADIOPRO

SI1005-C-GM

Manufacturer Part Number
SI1005-C-GM
Description
IC TXRX MCU + EZRADIOPRO
Manufacturer
Silicon Laboratories Inc
Datasheets

Specifications of SI1005-C-GM

Package / Case
42-QFN
Frequency
240MHz ~ 960MHz
Data Rate - Maximum
256kbps
Modulation Or Protocol
FSK, GFSK, OOK
Applications
General Purpose
Power - Output
13dBm
Sensitivity
-121dBm
Voltage - Supply
0.9 V ~ 1.8 V
Current - Receiving
18.5mA
Current - Transmitting
30mA
Data Interface
PCB, Surface Mount
Memory Size
32kB Flash, 4kB RAM
Antenna Connector
PCB, Surface Mount
Number Of Receivers
1
Number Of Transmitters
1
Wireless Frequency
240 MHz to 960 MHz
Interface Type
UART, SMBus, SPI, PCA
Output Power
13 dBm
Operating Supply Voltage
0.9 V to 3.6 V
Maximum Operating Temperature
+ 85 C
Mounting Style
SMD/SMT
Maximum Supply Current
4.1 mA
Minimum Operating Temperature
- 40 C
Modulation
FSK, GFSK, OOK
Protocol Supported
C2, SMBus
Core
8051
Program Memory Type
Flash
Program Memory Size
32 KB
Data Ram Size
4352 B
Supply Current (max)
4.1 mA
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Operating Temperature
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
336-1875-5

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
SI1005-C-GM
Manufacturer:
Silicon Labs
Quantity:
135
Si1000/1/2/3/4/5
28. Programmable Counter Array
The Programmable Counter Array (PCA0) provides enhanced timer functionality while requiring less CPU
intervention than the standard 8051 counter/timers. The PCA consists of a dedicated 16-bit counter/timer
and six 16-bit capture/compare modules. Each capture/compare module has its own associated I/O line
(CEXn) which is routed through the Crossbar to Port I/O when enabled. The counter/timer is driven by a
programmable timebase that can select between seven sources: system clock, system clock divided by
four, system clock divided by twelve, the external oscillator clock source divided by 8, Timer 0 overflows, or
an external clock signal on the ECI input pin. Each capture/compare module may be configured to operate
independently in one of six modes: Edge-Triggered Capture, Software Timer, High-Speed Output, Fre-
quency Output, 8 to 11-Bit PWM, or 16-Bit PWM (each mode is described in Section
“28.3. Capture/Compare Modules” on page 355). The external oscillator clock option is ideal for real-time
clock (RTC) functionality, allowing the PCA to be clocked by a precision external oscillator while the inter-
nal oscillator drives the system clock. The PCA is configured and controlled through the system controller's
Special Function Registers. The PCA block diagram is shown in Figure 28.1
Important Note: The PCA Module 5 may be used as a watchdog timer (WDT), and is enabled in this mode
following a system reset. Access to certain PCA registers is restricted while WDT mode is enabled .
See Section 28.4 for details.
352
Capture/Compare
Module 0
SYSCLK/12
Timer 0 Overflow
SYSCLK
External Clock/8
SYSCLK/4
ECI
Capture/Compare
Module 1
CLOCK
MUX
PCA
Figure 28.1. PCA Block Diagram
16-Bit Counter/Timer
Port I/O
Capture/Compare
Module 2
Crossbar
Rev. 1.0
Capture/Compare
Module 3
Capture/Compare
Module 4
Capture/Compare
Module 5 / WDT

Related parts for SI1005-C-GM