30068 Parallax Inc, 30068 Datasheet - Page 86

EMBEDDED BLUE TRANSCEIVER APPMOD

30068

Manufacturer Part Number
30068
Description
EMBEDDED BLUE TRANSCEIVER APPMOD
Manufacturer
Parallax Inc
Datasheet

Specifications of 30068

Frequency
2.4GHz
Data Rate - Maximum
90kBaud
Modulation Or Protocol
Bluetooth v1.1, Class 2
Applications
Bluetooth v1.1
Power - Output
-4dBm
Sensitivity
-85dBm
Voltage - Supply
5 V ~ 10 V
Current - Receiving
80mA
Current - Transmitting
250mA
Data Interface
PCB, Through Hole
Antenna Connector
PCB, Surface Mount
Operating Temperature
-20°C ~ 75°C
Package / Case
Module
Product
Microcontroller Accessories
Operating Supply Voltage
5 to 12 V
Memory Size
-
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
Q2239141

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
30068
Manufacturer:
SCC
Quantity:
38
Part Number:
3006892-04
Manufacturer:
JRC
Quantity:
346
Part Number:
3006892-04
Manufacturer:
FAIRCHILD/仙童
Quantity:
20 000
Communications
Step 2:
Page 80 ▪ EmbeddedBlue 500 User Manual
1. Using the BASIC Stamp Editor, on the File menu, click New.
2. Enter the following program code into the editor, replacing the device address with
In this step we will create a BASIC Stamp application to send data out the eb500 to
the Pocket PC. We will then download and run the application. The application for the
Pocket PC is too verbose to include in this manual; therefore, the application, along
with the source code, is available on the accompanying CD in the Samples folder. To
modify the Pocket PC application you will need eMbedded Visual C++ 4.0 with
Service Pack 2 and the SDK for Windows Mobile
This will create a new project window within the BASIC Stamp Editor.
the device address obtained from the Pocket PC. This application is available in
electronic form on the accompanying CD, in the Samples folder, in the file
HelloWorld.bs2.
'{$STAMP BS2}
nCount VAR BYTE
'Wait for the eb500 radio to be ready
PAUSE 1000
'Connect to the remote device
SEROUT 1,84,[“con 00:0C:84:00:05:29”,CR]
SERIN 0,84,[WAIT(“ACK”,CR)]
'Wait for the connection to be established and switch into data mode.
'When switching into data mode, a 300ms timeout is required to give the
'module enough time to make the change.
WaitForConnection:
HIGH 6
PAUSE 300
DEBUG "Connection established",CR
'Send "Hello World" ten times
FOR nCount = 1 to 10
Transmit Data from the BASIC Stamp to the Pocket PC
IF in5 = 0 THEN WaitForConnection
SEROUT 1,84,["Hello World",CR]
2003-based Pocket PCs.