PEF2256EV22NP Lantiq, PEF2256EV22NP Datasheet - Page 164

PEF2256EV22NP

Manufacturer Part Number
PEF2256EV22NP
Description
Manufacturer
Lantiq
Datasheet

Specifications of PEF2256EV22NP

Number Of Transceivers
1
Screening Level
Industrial
Mounting
Surface Mount
Operating Temperature (min)
-40C
Operating Temperature (max)
85C
Lead Free Status / RoHS Status
Supplier Unconfirmed
Table 41
Alarm
Yellow Alarm or
Remote Alarm
(RRA)
Excessive Zeros
(EXZD)
Pulse-Density
Violation
(PDEN)
Transmit Line
Short
(XLS)
Transmit
Ones-Density
(XLO)
1)
7.3.2
Data Sheet
RRA detection operates in the presence of 10
Automatic remote alarm (Yellow Alarm) access
If the receiver has lost its synchronization (FRS0.LFA) a remote alarm (yellow alarm)
is sent to the distant end automatically, if enabled by bit FMR2.AXRA. In synchronous
state the remote alarm bit is removed.
Automatic AIS to system interface
In asynchronous state the synchronizer enforces an AIS to the receive system
interface automatically. However, received data is switched through transparently if
bit FMR2.DAIS is set.
1)
Auto Modes
Summary of Alarm Detection and Release (T1/J1) (cont’d)
Detection Condition
RC1.RRAM = 0:
bit 2 = 0 in 255 consecutive time
slots or
FS-bit = 1 of frame12 in F12 (D4)
format or
8 1,8 0 in the DL channel (ESF)
RC1.RRAM = 1:
bit 2 = 0 in every time slot per
frame or
FS-bit = 1 of frame12 in F12 (D4)
format or
8 1,8 0 in the DL channel (ESF)
more than 7 (B8ZS code) or
more than 15 (AMI code)
contiguous zeros
less than N ones in each and
every time window of 8 (N+1)
time slots with N taking all values
of 1 to 23
or
more than 15 consecutive zeros
more than 3 pulse periods with
highly increased transmit line
current on XL1/2
32 consecutive zeros in the
transmit data stream on XL1/2
-3
bit error rate.
164
Clear Condition
RC1.RRAM = 0:
set conditions no longer detected.
RC1.RRAM = 1:
bit 2 = 0 not detected in 3
consecutive frames or
FS-bit not detected in 3
consecutive multiframes or
8 1,8 0 not detected for 3 times
in a row (ESF).
Latched Status: cleared on read
Latched Status: cleared on read
transmit line current limiter
inactive
Cleared with each transmitted
pulse
Functional Description T1/J1
Rev. 1.1, 2005-06-13
PEF 2256 H/E
FALC
®
56

Related parts for PEF2256EV22NP