PEF2256EV22NP Lantiq, PEF2256EV22NP Datasheet - Page 77

PEF2256EV22NP

Manufacturer Part Number
PEF2256EV22NP
Description
Manufacturer
Lantiq
Datasheet

Specifications of PEF2256EV22NP

Number Of Transceivers
1
Screening Level
Industrial
Mounting
Surface Mount
Operating Temperature (min)
-40C
Operating Temperature (max)
85C
Lead Free Status / RoHS Status
Supplier Unconfirmed
Figure 20
6.1.9
There are different definitions for detecting Loss-Of-Signal (LOS) alarms in the ITU-T
G.775 and ETS 300233. The FALC
is performed by generating an interrupt (if not masked) and activating a status bit.
Additionally a LOS status change interrupt is programmable by using register GCR.SCI.
Data Sheet
Detection:
An alarm is generated if the incoming data stream has no pulses (no transitions) for
a certain number (N) of consecutive pulse periods. “No pulse” in the digital receive
interface means a logical zero on pins RDIP/RDIN/ROID. A pulse with an amplitude
less than Q dB below nominal is the criteria for “no pulse” in the analog receive
interface (LIM1.DRS = 0). The receive signal level Q is programmable by three
E1/T1/J1
Transmit
E1/T1/J1
Receive
Line
Line
Loss-of-Signal Detection (E1)
Long Haul Protection Switching Application (E1)
®
56 covers all these standards. The LOS indication
77
XL1
XL2
RL1
RL2
XL1
XL2
RL1
RL2
stand-by device
active device
Functional Description E1
Rev. 1.1, 2005-06-13
RDO
RDO
PEF 2256 H/E
XDI
XDI
F56V2_Receiver_3
FALC
®
56