PEF2256EV22NP Lantiq, PEF2256EV22NP Datasheet - Page 256

PEF2256EV22NP

Manufacturer Part Number
PEF2256EV22NP
Description
Manufacturer
Lantiq
Datasheet

Specifications of PEF2256EV22NP

Number Of Transceivers
1
Screening Level
Industrial
Mounting
Surface Mount
Operating Temperature (min)
-40C
Operating Temperature (max)
85C
Lead Free Status / RoHS Status
Supplier Unconfirmed
Receive Control 0 (Read/Write)
Value after reset: 00
RC0
SWD
ASY4
CRCI
XCRCI
RDIS
Data Sheet
SWD
7
Service Word Condition Disable
0 =
1 =
Select Loss of Sync Condition
0 =
1 =
Automatic CRC4 Bit Inversion
If set, all CRC bits of one outgoing submultiframe are inverted in case
a CRC error is flagged for the previous received submultiframe. This
function is logically ored with RC0.XCRCI.
Transmit CRC4 Bit Inversion
If set, the CRC bits in the outgoing data stream are inverted before
transmission. This function is logically ored with RC0.CRCI.
Receive Data Input Sense
Digital interface, dual-rail:
0 =
1 =
Digital Interface, CMI:
0 =
1 =
ASY4
H
Standard operation. Three or four consecutive incorrect service
words (depending on bit RC0.ASY4) causes loss of
synchronization.
Errors in service words have no influence when in synchronous
state. However, they are used for the resynchronization
procedure.
Standard operation. Three consecutive incorrect FAS words or
three consecutive incorrect service words causes loss of
synchronization.
Four consecutive incorrect FAS words or four consecutive
incorrect service words causes loss of synchronization. The
service word condition is disabled by bit RC0.SWD.
Inputs RDIP/RDIN are active low
Inputs RDIP/RDIN are active high
Input ROID is active high
Input ROID is active low
CRCI
XCRCI
256
RDIS
RCO10
RCO9
Rev. 1.1, 2005-06-13
PEF 2256 H/E
RCO8
E1 Registers
0
FALC
(24)
®
56

Related parts for PEF2256EV22NP