DS26502L+ Maxim Integrated Products, DS26502L+ Datasheet - Page 101

IC T1/E1/J1 64KCC ELEMENT 64LQFP

DS26502L+

Manufacturer Part Number
DS26502L+
Description
IC T1/E1/J1 64KCC ELEMENT 64LQFP
Manufacturer
Maxim Integrated Products
Type
BITS Elementr
Datasheet

Specifications of DS26502L+

Voltage - Supply
3.135 V ~ 3.465 V
Operating Temperature
0°C ~ 70°C
Mounting Type
Surface Mount
Package / Case
64-LQFP
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Frequency-max
-
Output
-
Input
-
DS26502 T1/E1/J1/64KCC BITS Element
Select-IR-Scan
All test registers retain their previous state. The instruction register will remain unchanged during this
state. With JTMS LOW, a rising edge on JTCLK moves the controller into the capture-IR state and will
initiate a scan sequence for the instruction register. JTMS HIGH during a rising edge on JTCLK puts the
controller back into the test-logic-reset state.
Capture-IR
The capture-IR state is used to load the shift register in the instruction register with a fixed value. This
value is loaded on the rising edge of JTCLK. If JTMS is HIGH on the rising edge of JTCLK, the
controller will enter the exit1-IR state. If JTMS is LOW on the rising edge of JTCLK, the controller will
enter the shift-IR state.
Shift-IR
In this state, the shift register in the instruction register is connected between JTDI and JTDO and shifts
data one stage for every rising edge of JTCLK toward the serial output. The parallel register as well as all
test registers remain at their previous states. A rising edge on JTCLK with JTMS HIGH will move the
controller to the exit1-IR state. A rising edge on JTCLK with JTMS LOW will keep the controller in the
shift-IR state while moving data one stage thorough the instruction shift register.
Exit1-IR
A rising edge on JTCLK with JTMS LOW will put the controller in the pause-IR state. If JTMS is HIGH
on the rising edge of JTCLK, the controller will enter the update-IR state and terminate the scanning
process.
Pause-IR
Shifting of the instruction shift register is halted temporarily. With JTMS HIGH, a rising edge on JTCLK
will put the controller in the exit2-IR state. The controller will remain in the pause-IR state if JTMS is
LOW during a rising edge on JTCLK.
Exit2-IR
A rising edge on JTCLK with JTMS LOW will put the controller in the update-IR state. The controller
will loop back to shift-IR if JTMS is HIGH during a rising edge of JTCLK in this state.
Update-IR
The instruction code shifted into the instruction shift register is latched into the parallel output on the
falling edge of JTCLK as the controller enters this state. Once latched, this instruction becomes the
current instruction. A rising edge on JTCLK with JTMS LOW, will put the controller in the run-test-idle
state. With JTMS HIGH, the controller will enter the select-DR-scan state.