FDC37C669-MT SMSC, FDC37C669-MT Datasheet - Page 58

IC CTRLR SUPER I/O FLPPY 100TQFP

FDC37C669-MT

Manufacturer Part Number
FDC37C669-MT
Description
IC CTRLR SUPER I/O FLPPY 100TQFP
Manufacturer
SMSC
Datasheet

Specifications of FDC37C669-MT

Controller Type
I/O Controller
Interface
ISA Host
Voltage - Supply
4.5 V ~ 5.5 V
Current - Supply
25mA
Operating Temperature
0°C ~ 70°C
Mounting Type
Surface Mount
Package / Case
100-TQFP, 100-VQFP
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
638-1008

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
FDC37C669-MT
Manufacturer:
Microchip Technology
Quantity:
10 000
Read Deleted Data
This command is the same as the Read Data command,
only it operates on sectors that contain a Deleted Data
Address Mark at the beginning of a Data Field.
Read A Track
This command is similar to the Read Data command
except that the entire data field is read continuously from
each of the sectors of a track.
encountering a pulse on the nINDEX pin, the FDC
starts to read all data fields on the track as continuous
blocks of data without regard to logical sector numbers. If
the FDC finds an error in the ID or DATA CRC check
bytes, it continues to read data from the track and sets
the appropriate error bits at the end of the command.
The FDC compares the ID information read from each
sector with the specified value in the command
VALUE
SK BIT
0
0
1
1
Table 23 - Skip Bit vs. Read Deleted Data Command
Normal Data
Deleted Data
Normal Data
Deleted Data
DATA ADDRESS
ENCOUNTERED
MARK TYPE
Immediately after
SECTOR
READ?
Yes
Yes
Yes
No
58
Table 25 describes the effect of the SK bit on the Read
Deleted Data command execution and results.
Except where noted in Table 25, the C or R value of the
sector address is automatically incremented (see Table
26).
and sets the ND flag of Status Register 1 to a "1" if
there is no comparison. Multi-track or skip operations are
not allowed with this command. The MT and SK bits (bits
D7 and D5 of the first command byte respectively) should
always be set to "0".
This command terminates when the EOT specified
number of sectors has not been read. If the FDC does not
find an ID Address Mark on the diskette after the second
occurrence of a pulse on the IDX pin, then it sets the IC
code in Status Register 0 to "01" (abnormal termination),
sets the MA bit in Status Register 1 to "1", and terminates
the command.
CM BIT OF
ST2 SET?
Yes
Yes
No
No
RESULTS
Address not
incremented. Next
sector not
searched for.
Normal
termination.
Normal
termination. Sector
not read
("skipped").
Normal
termination.
DESCRIPTION OF
RESULTS