FDC37C669-MT SMSC, FDC37C669-MT Datasheet - Page 60

IC CTRLR SUPER I/O FLPPY 100TQFP

FDC37C669-MT

Manufacturer Part Number
FDC37C669-MT
Description
IC CTRLR SUPER I/O FLPPY 100TQFP
Manufacturer
SMSC
Datasheet

Specifications of FDC37C669-MT

Controller Type
I/O Controller
Interface
ISA Host
Voltage - Supply
4.5 V ~ 5.5 V
Current - Supply
25mA
Operating Temperature
0°C ~ 70°C
Mounting Type
Surface Mount
Package / Case
100-TQFP, 100-VQFP
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
638-1008

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
FDC37C669-MT
Manufacturer:
Microchip Technology
Quantity:
10 000
The Verify command is used to verify the data stored on
a disk. This command acts exactly like a Read Data
command except that no data is transferred to the host.
Data is read from the disk and CRC is computed and
checked against the previously-stored value.
Because data is not transferred to the host, TC (pin 25)
cannot be used to terminate this command. By setting
the EC bit to "1", an implicit TC will be issued to the FDC.
decremented to 0 (an SC value of 0 will verify 256
sectors).
NOTE: If MT is set to "1" and the SC value is greater than the number of remaining formatted sectors on Side 0, verifying
will continue on Side 1 of the disk.
This implicit TC will occur when the SC value has
MT
0
0
0
0
1
1
1
1
This
command
EC
0
0
1
1
0
0
1
1
Table 25 - Verify Command Result Phase Table
SC = DTL
EOT < # Sectors Per Side
SC = DTL
EOT > # Sectors Per Side
SC < # Sectors Remaining AND
EOT < # Sectors Per Side
SC > # Sectors Remaining OR
EOT > # Sectors Per Side
SC = DTL
EOT < # Sectors Per Side
SC = DTL
EOT > # Sectors Per Side
SC < # Sectors Remaining AND
EOT < # Sectors Per Side
SC > # Sectors Remaining OR
EOT > # Sectors Per Side
can
SC/EOT VALUE
also
be
60
terminated by setting the EC bit to "0" and the EOT value
equal to the final sector to be checked. If EC is set to "0",
DTL/SC should be programmed to 0FFH. Refer to Table
26 and Table 27 for information concerning the values of
MT and EC versus SC and EOT value.
Definitions:
# Sectors Per Side = Number of formatted sectors per
each side of the disk.
# Sectors Remaining = Number of formatted sectors left
which can be read, including side 1 of the disk if MT is set
to "1".
Success Termination
Result Phase Valid
Unsuccessful Termination
Result Phase Invalid
Successful Termination
Result Phase Valid
Unsuccessful Termination
Result Phase Invalid
Successful Termination
Result Phase Valid
Unsuccessful Termination
Result Phase Invalid
Successful Termination
Result Phase Valid
Unsuccessful Termination
Result Phase Invalid
TERMINATION RESULT