ATtiny461A Atmel Corporation, ATtiny461A Datasheet - Page 129

no-image

ATtiny461A

Manufacturer Part Number
ATtiny461A
Description
Manufacturer
Atmel Corporation
Datasheets

Specifications of ATtiny461A

Flash (kbytes)
4 Kbytes
Pin Count
20
Max. Operating Frequency
20 MHz
Cpu
8-bit AVR
# Of Touch Channels
8
Hardware Qtouch Acquisition
No
Max I/o Pins
16
Ext Interrupts
16
Usb Speed
No
Usb Interface
No
Spi
1
Twi (i2c)
1
Graphic Lcd
No
Video Decoder
No
Camera Interface
No
Adc Channels
11
Adc Resolution (bits)
10
Adc Speed (ksps)
15
Analog Comparators
1
Resistive Touch Screen
No
Temp. Sensor
Yes
Crypto Engine
No
Sram (kbytes)
0.25
Eeprom (bytes)
256
Self Program Memory
YES
Dram Memory
No
Nand Interface
No
Picopower
Yes
Temp. Range (deg C)
-40 to 85
I/o Supply Class
1.8 to 5.5
Operating Voltage (vcc)
1.8 to 5.5
Fpu
No
Mpu / Mmu
no / no
Timers
2
Output Compare Channels
6
Input Capture Channels
1
Pwm Channels
6
32khz Rtc
No
Calibrated Rc Oscillator
Yes

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ATtiny461A-MU
Manufacturer:
MICROCHIP/微芯
Quantity:
20 000
Part Number:
ATtiny461A-PU
Manufacturer:
HARRIS
Quantity:
101
Part Number:
ATtiny461A-SU
Manufacturer:
FSC
Quantity:
30 000
Part Number:
ATtiny461A-SU
Manufacturer:
ATMEL/爱特梅尔
Quantity:
20 000
Part Number:
ATtiny461A-SUR
Manufacturer:
HITTIE
Quantity:
2 140
Part Number:
ATtiny461A-XU
Manufacturer:
Atmel
Quantity:
1 974
8197C–AVR–05/11
Figure 13-4.
The data direction is not given by the physical layer. A protocol, like the one used by the TWI-
bus, must be implemented to control the data flow.
Figure 13-5.
Referring to the timing diagram
SDA
SCL
1. The start condition is generated by the master by forcing the SDA low line while keep-
2. In addition, the start detector will hold the SCL line low after the master has forced a
ing the SCL line high (A). SDA can be forced low either by writing a zero to bit 7 of the
USI Data Register, or by setting the corresponding bit in the PORTA register to zero.
Note that the Data Direction Register bit must be set to one for the output to be
enabled. The start detector logic of the slave device (see
detects the start condition and sets the USISIF Flag. The flag can generate an interrupt
if necessary.
negative edge on this line (B). This allows the slave to wake up from sleep or complete
other tasks before setting up the USI Data Register to receive the address. This is done
by clearing the start condition flag and resetting the counter.
SLAVE
MASTER
S
A B
Bit7
Bit7
Two-wire Mode Operation, Simplified Diagram
Two-wire Mode, Typical Timing Diagram
Bit6
Bit6
C
ADDRESS
1 - 7
Bit5
Bit5
Bit4
Bit4
Bit3
Bit3
R/W
(Figure
8
Bit2
Bit2
D
Bit1
Bit1
13-5), a bus transfer involves the following steps:
ACK
9
Bit0
Bit0
E
DATA
1 - 8
ATtiny261A/461A/861A
Two-wire Clock
Control Unit
ACK
9
PORTxn
Figure 13-6 on page
HOLD
SCL
DATA
1 - 8
SDA
SCL
SDA
SCL
ACK
9
VCC
130)
P
F
129

Related parts for ATtiny461A