SAM7L128 Atmel Corporation, SAM7L128 Datasheet - Page 454

no-image

SAM7L128

Manufacturer Part Number
SAM7L128
Description
Manufacturer
Atmel Corporation
Datasheets

Specifications of SAM7L128

Flash (kbytes)
128 Kbytes
Pin Count
144
Max. Operating Frequency
36 MHz
Cpu
ARM7TDMI
Hardware Qtouch Acquisition
No
Max I/o Pins
80
Ext Interrupts
80
Usb Speed
No
Usb Interface
No
Spi
1
Twi (i2c)
1
Uart
3
Segment Lcd
40
Graphic Lcd
No
Video Decoder
No
Camera Interface
No
Adc Channels
4
Adc Resolution (bits)
10
Adc Speed (ksps)
460
Resistive Touch Screen
No
Temp. Sensor
No
Crypto Engine
No
Sram (kbytes)
6
Self Program Memory
YES
Dram Memory
No
Nand Interface
No
Picopower
No
Temp. Range (deg C)
-40 to 85
I/o Supply Class
1.8/3.3
Operating Voltage (vcc)
1.8 to 3.6
Fpu
No
Mpu / Mmu
no / no
Timers
3
Output Compare Channels
3
Input Capture Channels
3
Pwm Channels
4
32khz Rtc
Yes
Calibrated Rc Oscillator
No
32.3
32.4
32.4.1
32.4.2
32.4.3
32.5
454
I/O Lines Description
Product Dependencies
Functional Description
AT91SAM7L128/64 Preliminary
I/O Lines
Power Management
Interrupt Sources
Each channel outputs one waveform on one external I/O line.
Table 32-1.
The pins used for interfacing the PWM may be multiplexed with PIO lines. The programmer must
first program the PIO controller to assign the desired PWM pins to their peripheral function. If I/O
lines of the PWM are not used by the application, they can be used for other purposes by the
PIO controller.
All of the PWM outputs may or may not be enabled. If an application requires only four channels,
then only four PIO lines will be assigned to PWM outputs.
The PWM is not continuously clocked. The programmer must first enable the PWM clock in the
Power Management Controller (PMC) before using the PWM. However, if the application does
not require PWM operations, the PWM clock can be stopped when not needed and be restarted
later. In this case, the PWM will resume its operations where it left off.
Configuring the PWM does not require the PWM clock to be enabled.
The PWM interrupt line is connected on one of the internal sources of the Advanced Interrupt
Controller. Using the PWM interrupt requires the AIC to be programmed first. Note that it is not
recommended to use the PWM interrupt line in edge sensitive mode.
The PWM macrocell is primarily composed of a clock generator module and
Name
PWMx
– Clocked by the system clock, MCK, the clock generator module provides 13 clocks.
– Each channel can independently choose one of the clock generator outputs.
– Each channel generates an output waveform with attributes that can be defined
independently for each channel through the user interface registers.
I/O Line Description
Description
PWM Waveform Output for channel x
6257A–ATARM–20-Feb-08
4
channels.
Type
Output