SAM7L128 Atmel Corporation, SAM7L128 Datasheet - Page 70

no-image

SAM7L128

Manufacturer Part Number
SAM7L128
Description
Manufacturer
Atmel Corporation
Datasheets

Specifications of SAM7L128

Flash (kbytes)
128 Kbytes
Pin Count
144
Max. Operating Frequency
36 MHz
Cpu
ARM7TDMI
Hardware Qtouch Acquisition
No
Max I/o Pins
80
Ext Interrupts
80
Usb Speed
No
Usb Interface
No
Spi
1
Twi (i2c)
1
Uart
3
Segment Lcd
40
Graphic Lcd
No
Video Decoder
No
Camera Interface
No
Adc Channels
4
Adc Resolution (bits)
10
Adc Speed (ksps)
460
Resistive Touch Screen
No
Temp. Sensor
No
Crypto Engine
No
Sram (kbytes)
6
Self Program Memory
YES
Dram Memory
No
Nand Interface
No
Picopower
No
Temp. Range (deg C)
-40 to 85
I/o Supply Class
1.8/3.3
Operating Voltage (vcc)
1.8 to 3.6
Fpu
No
Mpu / Mmu
no / no
Timers
3
Output Compare Channels
3
Input Capture Channels
3
Pwm Channels
4
32khz Rtc
Yes
Calibrated Rc Oscillator
No
14.4
14.4.1
14.4.2
14.4.3
14.4.4
70
Functional Description
AT91SAM7L128/64 Preliminary
Reference Clock
Timing
Alarm
Error Checking
The RTC provides a full binary-coded decimal (BCD) clock that includes century (19/20), year
(with leap years), month, date, day, hours, minutes and seconds.
The valid year range is 1900 to 2099, a two-hundred-year Gregorian calendar achieving full Y2K
compliance.
The RTC can operate in 24-hour mode or in 12-hour mode with an AM/PM indicator.
Corrections for leap years are included (all years divisible by 4 being leap years, including year
2000). This is correct up to the year 2099.
After hardware reset, the calendar is initialized to Thursday, January 1, 1998.
The reference clock is Slow Clock (SLCK). It can be driven by the Atmel cell OSC55 or OSC56
(or an equivalent cell) and an external 32.768 kHz crystal.
During low power modes of the processor (idle mode), the oscillator runs and power consump-
tion is critical. The crystal selection has to take into account the current consumption for power
saving and the frequency drift due to temperature effect on the circuit for time accuracy.
The RTC is updated in real time at one-second intervals in normal mode for the counters of sec-
onds, at one-minute intervals for the counter of minutes and so on.
Due to the asynchronous operation of the RTC with respect to the rest of the chip, to be certain
that the value read in the RTC registers (century, year, month, date, day, hours, minutes, sec-
onds) are valid and stable, it is necessary to read these registers twice. If the data is the same
both times, then it is valid. Therefore, a minimum of two and a maximum of three accesses are
required.
The RTC has five programmable fields: month, date, hours, minutes and seconds.
Each of these fields can be enabled or disabled to match the alarm condition:
Depending on the combination of fields enabled, a large number of possibilities are available to
the user ranging from minutes to 365/366 days.
Verification on user interface data is performed when accessing the century, year, month, date,
day, hours, minutes, seconds and alarms. A check is performed on illegal BCD entries such as
illegal date of the month with regard to the year and century configured.
If one of the time fields is not correct, the data is not loaded into the register/counter and a flag is
set in the validity register. The user can not reset this flag. It is reset as soon as an acceptable
value is programmed. This avoids any further side effects in the hardware. The same procedure
is done for the alarm.
The following checks are performed:
• If all the fields are enabled, an alarm flag is generated (the corresponding flag is asserted
• If only the “seconds” field is enabled, then an alarm is generated every minute.
and an interrupt generated if enabled) at a given month, date, hour/minute/second.
6257A–ATARM–20-Feb-08

Related parts for SAM7L128